09.b1 Staff Report Tender 2 Replacement
Staff Report
Date of Meeting: December, 19th 2023
To: City Council
From: Mike Hinz, Fire Chief
Re: Tender 2 replacement
Background:
The current tender is a 2003 on a Peterbilt chassis. This truck has been a very good and useful truck, but is
beginning to show signs of its age. Currently the pump is leaking and has had issues with not starting. We are
also chasing oil and antifreeze leaks. The current truck is also not meeting the needs of our department and
surrounding departments. We are now using the pump on the tender to move water instead of using multiple
drop tanks. This allows more flexibility in setup and makes for a safer scene. There are also new safety
standards that will be on the new truck, rollover control, better scene lighting, backup camera, tire monitor
system, plus other items
This will also be a freightliner chassis which we already have 2 others of. This will make parts and
supplies better to control and save time and money.
One of the questions that always is asked is what is the milage. This truck has 10,000 miles and just over
1,000 hours. Yes, this is low miles, but this truck is 20 years old and has been sitting ready and full of water.
Over time having a truck sit fully loaded does wear parts out, so not only have safety items changed but any part
that has rubber of plastic in it, is to the point that it is brittle and degraded. There are options to refurbish this
truck. With that said a refurb will cost about 50% of new and not include any of the safety equipment or updates
we are looking for. A full refurb with a new chassis is going to be closer to 75% of the cost and we would not
get the 20-year life that we will get from this new truck. Most departments that do a refurbish of a truck will
give it a life of 5-15 years depending on how full of a refurbish they do. We don’t think this is a good decision
for Scandia.
Fire trucks have drastically increased in cost over the last few years. We did do a lot of research to find
the best truck at the lowest price. We did check 2 other vendors they were $415,000 and $577,000. This
company is part of SourceWell so there is no need to bid this truck and we did get other pricing for a similar
truck and have picked the low bid.
Issue:
Should the city council approve the purchase of a replacement tender?
Proposal Details:
Purchase a replacement Tender from Midwest Fire in the amount of $396,304.40. The new truck will
have an estimated 19-month lead time.
Fiscal Impact:
The CIP has $425,000 for the replacement of Tender 2. The estimate from Midwest Fire is $396,304.40
which is under budget by $28,695.60.
Options:
(1) Approve purchase of replacement tender
(2) Deny the purchase of replacement tender
Recommendation:
Option (1).
THREE (3) NEWTON 10" STAINLESS STEEL
DUMP VALVES WITH FOLDING SHOOTS
SIX (6) WHELEN M6 LED INTERSECTION LIGHTS
THREE (3) EACH SIDE
SIX (6) WHELEN M9V2R WARNING AND SCENE LIGHTS
TWO (2) EACH SIDE
TWO (2) REAR
SIX (6) LED GROUND LIGHTS
THREE (3) EACH SIDE
TWO (2) MINI BROW LIGHTONE (1) CAB
ONE (1) REAR
FREIGHTLINER M2 106 CHASSIS
TWO (2) FRONT FOLDING STEPSONE (1) EACH SIDE
GRAB RAIL
WHELEN JUSTICE SERIES LIGHT BAR
KUSSMAUL
FRONT MONITOR
ALL POLY SWEEP OUT STYLE COMPARTMENTS WITH
DOOR ACTIVATED LED LIGHTING
65" WIDE X 26" TALL OPENING (67 X 30 ROUGH)67" WIDE X 35" TALL X 26" DEEP MAX DIMENSIONS
NFPA COMPLIANT 2000 GALLON POLYPROPYLENE TANK
(LIFETIME WARRANTY)
RACK STORAGE FOR
TWO (2) 5" X 10' HARD SUCTION HOSE
TWO (2) TOW RINGS
NFPA COMPLIANT WHELEN LED WARNING
LIGHT PACKAGE & SIREN/SPEAKER
WHELEN 295SL SIREN
LSP1000 PUMPHOUSE
TWO (2) 36" LIGHT
ONE (1) EACH SIDE
23052
THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE SOLE PROPERTY OF MIDWEST FIRE (MWF). ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF MIDWEST FIRE IS
STRICTLY PROHIBITED. THE DRAWING IS APPROXIMATE AND FOR REFERENCE PURPOSES ONLY.
SPECIFICATIONS SHALL BE THE FINAL AUTHORITY DEFINING WHAT IS SUPPLIED ON THE APPARATUS.SHEET 1 OF 4
PREPARED FOR BY C. NEKALISCANDIA, MN
DRAWING NUMBER
NOTE: ALL DIMENSIONS GIVEN IN THIS DRAWING ARE ESTIMATES, AND MAY VARY UP TO 3 INCHES. IF ANY DIMENSIONS ARE CRITICAL, PLEASE NOTIFY YOUR SALESPERSON.
10" HOSE BED
66 12 " HOSE BED
4" DIRECT TANK FILL
RECESSED TRAFFIC ADVISOR
NFPA COMPLIANT RED AND YELLOW CHEVRON STRIPING
NFPA COMPLIANT LED LIGHTED FOLDING STEPS
NFPA COMPLIANT GRAB RAIL
HOSE REEL
NFPA COMPLIANT LED DOT LIGHTING
REAR VIEW CAMERA
SPANNER WRENCH SET
STORZ WRENCH SET
TANK LEVEL GAUGE
FOLDING LADDER
FILL TOWER
FULL WIDTH & LENGTH HOSE BED
(COVER NOT SHOWN)
PRE-CONNECTED HOSE CROSSLAYS
(COVER NOT SHOWN)
23052 SHEET 2 OF 4
PREPARED FOR BY C. NEKALISCANDIA, MN
DRAWING NUMBER
NOTE: ALL DIMENSIONS GIVEN IN THIS DRAWING ARE ESTIMATES, AND MAY VARY UP TO 3 INCHES. IF ANY DIMENSIONS ARE CRITICAL, PLEASE NOTIFY YOUR SALESPERSON.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE SOLE PROPERTY OF MIDWEST FIRE (MWF). ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF MIDWEST FIRE IS
STRICTLY PROHIBITED. THE DRAWING IS APPROXIMATE AND FOR REFERENCE PURPOSES ONLY.
SPECIFICATIONS SHALL BE THE FINAL AUTHORITY DEFINING WHAT IS SUPPLIED ON THE APPARATUS.
162" TANK LENGTH
2" 36" 4"
349 12 "29'-1 12 " EST LENGTH
0"
25"2'-1" TAILBOARD
61"5'-1" CATWALK
42 12 "3'-6 12 " STEP
72"6'-0" REFERENCE
99 12 "8'-3 12 " HOSE BED
109 12 "9'-1 12 " BODY HEIGHT
115"9'-7" EST HEIGHT
216" WB
150" CA
65" WIDE X 26" TALL OPENING (67 X 30 ROUGH)
67" WIDE X 35" TALL X 26" DEEP MAX DIMENSIONS
2100 GALLON PORTABLE TANK WITH FRONT
ALUMINUM TREAD-BRITE WIND DEFLECTOR
23052 SHEET 3 OF 4
PREPARED FOR BY C. NEKALISCANDIA, MN
DRAWING NUMBER
NOTE: ALL DIMENSIONS GIVEN IN THIS DRAWING ARE ESTIMATES, AND MAY VARY UP TO 3 INCHES. IF ANY DIMENSIONS ARE CRITICAL, PLEASE NOTIFY YOUR SALESPERSON.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE SOLE PROPERTY OF MIDWEST FIRE (MWF). ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF MIDWEST FIRE IS
STRICTLY PROHIBITED. THE DRAWING IS APPROXIMATE AND FOR REFERENCE PURPOSES ONLY.
SPECIFICATIONS SHALL BE THE FINAL AUTHORITY DEFINING WHAT IS SUPPLIED ON THE APPARATUS.
23052 SHEET 4 OF 4
PREPARED FOR BY C. NEKALISCANDIA, MN
DRAWING NUMBER
NOTE: ALL DIMENSIONS GIVEN IN THIS DRAWING ARE ESTIMATES, AND MAY VARY UP TO 3 INCHES. IF ANY DIMENSIONS ARE CRITICAL, PLEASE NOTIFY YOUR SALESPERSON.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS THE SOLE PROPERTY OF MIDWEST FIRE (MWF). ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF MIDWEST FIRE IS
STRICTLY PROHIBITED. THE DRAWING IS APPROXIMATE AND FOR REFERENCE PURPOSES ONLY.
SPECIFICATIONS SHALL BE THE FINAL AUTHORITY DEFINING WHAT IS SUPPLIED ON THE APPARATUS.
This document contains a quote that is subject to change and is not a legally binding document.
craig@midwestfire.comEmail
Craig NekaliPrepared By
15040 Scandia Trail North
Scandia, MN 55073
USA
Mailing Address
mike.hinz@scandiafire.comEmail
(651) 433-4383Phone
Mike HinzContact Name
City of Scandia Fire DepartmentAccount Name
901 Commerce Road
P.O. Box 524
Luverne, MN 56156-0524
US
Company Address
12/12/2023Created Date
00006996Quote Number
Apparatus
Product Quote Description Quantity
A) 1.01.02 All-Poly Series 2000 Gallon, "T" Style 1.00
A) 1.02.00 Rear Fill Tower, Center 1.00
B) 2.00.04 Direct Fill, Rear, Street Side 4" Storz 1.00
B) 2.02.00.01 Tank Level Gauges, Automatic Off, at 10mph 1.00
B) 2.02.08.01 IC, Soft Glo Series Tank Level Gauge, Street Side Pump Panel - Master 1.00
B) 2.02.08.03 IC, Soft Glo Series Tank Level Gauge, Rear Street Side 1.00
B) 2.02.08.11 IC, Soft Glo Mini Dash Tank Level Gauge, Installed on the center console 1.00
B) 2.03.02 Hydrant (1) One & (2) Two Spanner Wrenches, Curb Side Rear Panel 1.00
B) 2.04.01 Storz Spanner Wrenches, (4) Four, Street Side Rear Panel 1.00
C) 3.00.01.03 Rear Dump, Center, SST, w/ 12" Flip Chute, Top Handle 1.00
C) 3.00.03 Rear Dump, Street Side, SST, w/36" Tele Chute 1.00
C) 3.00.04 Rear Dump, Curb Side, SST, w/36" Tele Chute 1.00
D) 4.00.08 Portable Tank Carrier, 3000 Gallons, Curb Side 1.00
D) 4.01.01 Portable Tank Carrier with Front Aluminum Tread-brite Wind Deflector 1.00
D) 4.06.08 Portable Tank, 3000 Gallon, Alum Frame, (See Spec for Color), 159" x 29"1.00
F) 6.00.01 Street Side, Front Low Compartment 1.00
F) 6.01.01 Curb Side, Front Low Compartment 1.00
F) 6.02.03.13 Adjustable Shelf, Street Side, Front, Lower 1.00
F) 6.02.03.15 Adjustable Shelf, Curb Side, Front, Lower 1.00
F) 6.960 60" Roll-Up Door 2.00
G) 7.02.01 Rear Step, 12" Deep 1.00
H) 8.00.01.02 Tank Grab Rails, (1) Vertical, Rear, Street Side 1.00
H) 8.00.04.01 Tank Grab Rail, (1) One, Front, Street Side 1.00
H) 8.00.05.01 Tank Grab Rail, (1) One, Front, Curb Side 1.00
H) 8.01.02.01 Front Folding Steps, Street Side, (1) One 1.00
Sourcewell Contract Pricing
This document contains a quote that is subject to change and is not a legally binding document.
H) 8.01.03.01 Front Folding Steps, Curb Side, (1) One 1.00
H) 8.01.04.02 Lower Level Rear Folding Steps, Chrome Plated, Street Side, (1) One 1.00
H) 8.02.02 Folding Hose Bed Access Ladder - Curb Side 1.00
I) 9.02.01.02 Quad-Cluster Tail Light Package, Whelen M6 Series 1.00
I) 9.03.04 Antenna Mounting Base, MWF Supplied 1.00
I) 9.04.01.02 Camera, Rear View, RearViewSafety, w/out GPS 1.00
I) 9.06.05.09 Outlet, 110V, Shoreline, Rear of Center Console, Facing Rear 1.00
I) 9.06.06.09 12V Power Strip, Inside Center Console, Wired to Chassis Battery 1.00
I) 9.06.06.10 12V Power Strip, Inside Center Console, Wired to Master Switch 1.00
J) 10.00.01 Center Console for Freightliner Chassis 1.00
J) 10.01.01.01 Light Bar, LED, Low-Profile, Model Whelen, #JE2NFPA, Red 1.00
J) 10.01.05 Federal Signal Opticom Infrared System, Model 794-AH 1.00
J) 10.02.01.02 Whelen 295SLSA1 Siren w/ Speaker Mounted flush mounted, Street Side 1.00
J) 10.04.04.02 Lower Level Lights, Front/Rear Flashers, Red Light, M6 Series LED, Four (4) Total 1.00
J) 10.05.04 Intersection Lights, M6 Series LED, Red Light, (6) Six, (3) Three Each Side 1.00
J) 10.06.08.02 Side/Rear Scene/Flasher, Red Light, M9V2, (2) Each Side Tank, (2) Rear of Apparatus, (6) Six Total, Chrome Bezel 1.00
J) 10.07.05 Automatic Reverse Scene Lighting 1.00
J) 10.07.37.01 Brow Light, FireTech 46" LED, Mounted Upper Center of Tank, (1) Street Side, (1) Curb Side, (2) Total, White
Housing 1.00
J) 10.09.02 Ground Lights, LED, (6) Six 1.00
J) 10.10.01.01 Wigwag Headlights - OEM Installed 1.00
J) 10.10.02.03 Whelen Traffic Advisor model TAL65 - Recessed Poly Box Built into the Rear of Tank 1.00
J) 10.10.06.01 Step Lights, LED, (4) Four, Illuminate Chassis Steps 1.00
J) 10.10.07.01 Mini-Brow Light 9 LED, Fire Tech, HiViz LED, One (1), 10-Degree Spot & 60-Degree Flood, White Housing 2.00
K) 11.00.01.02 Paint, Color Matched, Single Tone, 1900 - 2000 Gallon 1.00
K) 11.05.03.01 Reflective Striping Inside of Chassis Doors, Single Cab 1.00
K) 11.05.05.01 Reflective Striping, <Color>, (1" x 6" x 1"), Straight on Truck & Body, Single Axle 1.00
K) 11.06.05 Rear Chevron, Diamond Grade Pattern, 100% of Rear, Red/Fluorescent Yellow, no Shadow Flame 1.00
M)
13.03.05.01 Pump, Darley LSP 1000 PTO, Side Control, 36" Pumphouse 1.00
M)
13.03.25.01 PTO Auto Governor Option, Fire Research “Pump Boss 400 Series Auto Governor”1.00
M) 13.05.01 Primer Pump Option, Rotary Vane 1.00
M)
13.06.01.01 Suction Intake, 2 1/2" Gated, Street Side, (1) One 1.00
M)
13.07.01.02 Side Control Pump Panel Discharges, 2 1/2", Street Side, (2) Two 1.00
M)
13.07.01.03 Side Control Pump Panel Discharges, 2 1/2", Curb Side, (1) One 1.00
M)
13.07.01.08 Side Control Pump Panel Discharge, 4", Curb Side, Electric, (1) One 1.00
Sourcewell Contract Pricing
This document contains a quote that is subject to change and is not a legally binding document.
M)
13.07.50.09
Install Discharge Adapter, 4" NSTF Swivel Rocker Lug X 4" Storz Lock & Cap, 30 Degree Elbow On < >1.00
M)
13.08.08.01 Deck Gun Port only 1.00
M)
13.08.09.01 Elkhart BrushHawk Electric Front Monitor, Center of Bumper 1.00
M)
13.09.01.01 Tank Fill Valve 2", Side Control 1.00
M)
13.09.03.01 Tank to Pump 3", Manual Controls, Side Control 1.00
M) 13.11.02 Pump House Heat Control, Pump House Heater, 29,380 BTU/hr 1.00
M) 13.11.04 Pump House Heat Control, Pump Compartment Heat Pan 1.00
M) 13.12.01 Pump Certification, MWF Calibration 1.00
N) 14.08.01 Hose Cross Lay Above Side Control Pump 1.00
N) 14.09.02 Pre-connected Cross Lays, Two (2) 1 1/2" NST Male, 2" Valve 1.00
N)
14.10.01.02 Cross Lay Divider, (2) Two Ajustable Dividers, 3/16" Aluminum 1.00
N)
14.10.04.01 Cross Lay Vinyl Cover, Mesh Ends, Black 1.00
N)
14.11.00.01 Hose Bed, Full Length & Width of Tank, 10" Tall Walls 1.00
N)
14.11.01.02 Hose Bed Divider, Two (2)1.00
N)
14.11.02.01 Hose Bed Cover, Black, 1500-2000 Gallon 1.00
O)
15.00.06.03 (2) Hard Suct Trays, 4 1/2"-6", Street Side of Tank 1.00
P) 16.00.09 Electric Hose Reel With Rubber Hose, 100' of 1", Below Rear Dump Valve, Behind Rear Panel 1.00
P) 16.02.01 Hose Reel Blowout 1.00
Q)
17.01.02.02 Hub and Lugnut Covers, Single Axle, OEM Install 1.00
Q) 17.03.02 Pump Plus 1000 System, 15-amp, manual plug-in beneath the street side chassis door 1.00
Q)
17.08.00.03 Air Horns installed on Each Side of the Hood, (2) Two, Chassis OEM Installed Lanyard Controls 1.00
Q)
17.10.01.03 Tire Pressure Indicator, OEM installed 1.00
Q)
17.10.04.03 Heat Exchanger, Darley Pump 1.00
Q)
17.10.12.02 Engine Compartment Light, LED, OEM Installed 1.00
Q)
17.10.15.01 Power Take Off (PTO), OEM Installed 1.00
Q)
17.11.01.01 Chassis Exhaust, Standard Modifications 1.00
R) 18.08.03 Wheel Chocks, Rubber, (2) Two, Connected by Rope, in Spare Compartment 1.00
Sourcewell Contract Pricing
This document contains a quote that is subject to change and is not a legally binding document.
$396,304.40Total Price
R) 18.10.10 PVC Flex Hard Suction Hose, 5" X 10', (1) One 2.00
R) 18.19 DOT Essential Kit 1.00
S) 19.01 2025 Freightliner Chassis estimate, M2-106 1.00
S) 19.01 Freightliner Chassis 1.00
S) 19.09 Freightliner - PTO Pump - Add 1.00
Z) NOR (1) NOR 5709, Gravity feed garden hose fitting from tank to pump panel with ball valve shutoff.1.00
Z) NOR (2) NOR 5712, MIV Electric master intake valve curbside, and manual butterfly valve street side.1.00
Z) NOR (3) NOR 5711, Whelen Arges remote controlled light on roof mounted on bracket to rear of lightbar 1.00
Z) NOR (4) NOR 2038, 6" NSTF x 5" NSTM Adapter for master intakes.2.00
Sourcewell Contract Pricing
This document contains a quote that is subject to change and is not a legally binding document.
craig@midwestfire.comEmail
Craig NekaliPrepared By
15040 Scandia Trail North
Scandia, MN 55073
USA
Mailing Address
mike.hinz@scandiafire.comEmail
(651) 433-4383Phone
Mike HinzContact Name
City of Scandia Fire DepartmentAccount Name
901 Commerce Road
P.O. Box 524
Luverne, MN 56156-0524
US
Company Address
12/12/2023Created Date
00006995Quote Number
Apparatus
Product Quote Description Quantity
A) 1.01.02 All-Poly Series 2000 Gallon, "T" Style 1.00
A) 1.02.00 Rear Fill Tower, Center 1.00
B) 2.00.04 Direct Fill, Rear, Street Side 4" Storz 1.00
B) 2.02.00.01 Tank Level Gauges, Automatic Off, at 10mph 1.00
B) 2.02.08.01 IC, Soft Glo Series Tank Level Gauge, Street Side Pump Panel - Master 1.00
B) 2.02.08.03 IC, Soft Glo Series Tank Level Gauge, Rear Street Side 1.00
B) 2.02.08.11 IC, Soft Glo Mini Dash Tank Level Gauge, Installed on the center console 1.00
B) 2.03.02 Hydrant (1) One & (2) Two Spanner Wrenches, Curb Side Rear Panel 1.00
B) 2.04.01 Storz Spanner Wrenches, (4) Four, Street Side Rear Panel 1.00
C) 3.00.01.03 Rear Dump, Center, SST, w/ 12" Flip Chute, Top Handle 1.00
C) 3.00.03 Rear Dump, Street Side, SST, w/36" Tele Chute 1.00
C) 3.00.04 Rear Dump, Curb Side, SST, w/36" Tele Chute 1.00
D) 4.00.08 Portable Tank Carrier, 3000 Gallons, Curb Side 1.00
D) 4.01.01 Portable Tank Carrier with Front Aluminum Tread-brite Wind Deflector 1.00
D) 4.06.08 Portable Tank, 3000 Gallon, Alum Frame, (See Spec for Color), 159" x 29"1.00
F) 6.00.01 Street Side, Front Low Compartment 1.00
F) 6.01.01 Curb Side, Front Low Compartment 1.00
F) 6.02.03.13 Adjustable Shelf, Street Side, Front, Lower 1.00
F) 6.02.03.15 Adjustable Shelf, Curb Side, Front, Lower 1.00
F) 6.960 60" Roll-Up Door 2.00
G) 7.02.01 Rear Step, 12" Deep 1.00
H) 8.00.01.02 Tank Grab Rails, (1) Vertical, Rear, Street Side 1.00
H) 8.00.04.01 Tank Grab Rail, (1) One, Front, Street Side 1.00
H) 8.00.05.01 Tank Grab Rail, (1) One, Front, Curb Side 1.00
H) 8.01.02.01 Front Folding Steps, Street Side, (1) One 1.00
Standard Pricing
This document contains a quote that is subject to change and is not a legally binding document.
H) 8.01.03.01 Front Folding Steps, Curb Side, (1) One 1.00
H) 8.01.04.02 Lower Level Rear Folding Steps, Chrome Plated, Street Side, (1) One 1.00
H) 8.02.02 Folding Hose Bed Access Ladder - Curb Side 1.00
I) 9.02.01.02 Quad-Cluster Tail Light Package, Whelen M6 Series 1.00
I) 9.03.04 Antenna Mounting Base, MWF Supplied 1.00
I) 9.04.01.02 Camera, Rear View, RearViewSafety, w/out GPS 1.00
I) 9.06.05.09 Outlet, 110V, Shoreline, Rear of Center Console, Facing Rear 1.00
I) 9.06.06.09 12V Power Strip, Inside Center Console, Wired to Chassis Battery 1.00
I) 9.06.06.10 12V Power Strip, Inside Center Console, Wired to Master Switch 1.00
J) 10.00.01 Center Console for Freightliner Chassis 1.00
J) 10.01.01.01 Light Bar, LED, Low-Profile, Model Whelen, #JE2NFPA, Red 1.00
J) 10.01.05 Federal Signal Opticom Infrared System, Model 794-AH 1.00
J) 10.02.01.02 Whelen 295SLSA1 Siren w/ Speaker Mounted flush mounted, Street Side 1.00
J) 10.04.04.02 Lower Level Lights, Front/Rear Flashers, Red Light, M6 Series LED, Four (4) Total 1.00
J) 10.05.04 Intersection Lights, M6 Series LED, Red Light, (6) Six, (3) Three Each Side 1.00
J) 10.06.08.02 Side/Rear Scene/Flasher, Red Light, M9V2, (2) Each Side Tank, (2) Rear of Apparatus, (6) Six Total, Chrome Bezel 1.00
J) 10.07.05 Automatic Reverse Scene Lighting 1.00
J) 10.07.37.01 Brow Light, FireTech 46" LED, Mounted Upper Center of Tank, (1) Street Side, (1) Curb Side, (2) Total, White
Housing 1.00
J) 10.09.02 Ground Lights, LED, (6) Six 1.00
J) 10.10.01.01 Wigwag Headlights - OEM Installed 1.00
J) 10.10.02.03 Whelen Traffic Advisor model TAL65 - Recessed Poly Box Built into the Rear of Tank 1.00
J) 10.10.06.01 Step Lights, LED, (4) Four, Illuminate Chassis Steps 1.00
J) 10.10.07.01 Mini-Brow Light 9 LED, Fire Tech, HiViz LED, One (1), 10-Degree Spot & 60-Degree Flood, White Housing 2.00
K) 11.00.01.02 Paint, Color Matched, Single Tone, 1900 - 2000 Gallon 1.00
K) 11.05.03.01 Reflective Striping Inside of Chassis Doors, Single Cab 1.00
K) 11.05.05.01 Reflective Striping, <Color>, (1" x 6" x 1"), Straight on Truck & Body, Single Axle 1.00
K) 11.06.05 Rear Chevron, Diamond Grade Pattern, 100% of Rear, Red/Fluorescent Yellow, no Shadow Flame 1.00
M)
13.03.05.01 Pump, Darley LSP 1000 PTO, Side Control, 36" Pumphouse 1.00
M)
13.03.25.01 PTO Auto Governor Option, Fire Research “Pump Boss 400 Series Auto Governor”1.00
M) 13.05.01 Primer Pump Option, Rotary Vane 1.00
M)
13.06.01.01 Suction Intake, 2 1/2" Gated, Street Side, (1) One 1.00
M)
13.07.01.02 Side Control Pump Panel Discharges, 2 1/2", Street Side, (2) Two 1.00
M)
13.07.01.03 Side Control Pump Panel Discharges, 2 1/2", Curb Side, (1) One 1.00
M)
13.07.01.08 Side Control Pump Panel Discharge, 4", Curb Side, Electric, (1) One 1.00
Standard Pricing
This document contains a quote that is subject to change and is not a legally binding document.
M)
13.07.50.09
Install Discharge Adapter, 4" NSTF Swivel Rocker Lug X 4" Storz Lock & Cap, 30 Degree Elbow On < >1.00
M)
13.08.08.01 Deck Gun Port only 1.00
M)
13.08.09.01 Elkhart BrushHawk Electric Front Monitor, Center of Bumper 1.00
M)
13.09.01.01 Tank Fill Valve 2", Side Control 1.00
M)
13.09.03.01 Tank to Pump 3", Manual Controls, Side Control 1.00
M) 13.11.02 Pump House Heat Control, Pump House Heater, 29,380 BTU/hr 1.00
M) 13.11.04 Pump House Heat Control, Pump Compartment Heat Pan 1.00
M) 13.12.01 Pump Certification, MWF Calibration 1.00
N) 14.08.01 Hose Cross Lay Above Side Control Pump 1.00
N) 14.09.02 Pre-connected Cross Lays, Two (2) 1 1/2" NST Male, 2" Valve 1.00
N)
14.10.01.02 Cross Lay Divider, (2) Two Ajustable Dividers, 3/16" Aluminum 1.00
N)
14.10.04.01 Cross Lay Vinyl Cover, Mesh Ends, Black 1.00
N)
14.11.00.01 Hose Bed, Full Length & Width of Tank, 10" Tall Walls 1.00
N)
14.11.01.02 Hose Bed Divider, Two (2)1.00
N)
14.11.02.01 Hose Bed Cover, Black, 1500-2000 Gallon 1.00
O)
15.00.06.03 (2) Hard Suct Trays, 4 1/2"-6", Street Side of Tank 1.00
P) 16.00.09 Electric Hose Reel With Rubber Hose, 100' of 1", Below Rear Dump Valve, Behind Rear Panel 1.00
P) 16.02.01 Hose Reel Blowout 1.00
Q)
17.01.02.02 Hub and Lugnut Covers, Single Axle, OEM Install 1.00
Q) 17.03.02 Pump Plus 1000 System, 15-amp, manual plug-in beneath the street side chassis door 1.00
Q)
17.08.00.03 Air Horns installed on Each Side of the Hood, (2) Two, Chassis OEM Installed Lanyard Controls 1.00
Q)
17.10.01.03 Tire Pressure Indicator, OEM installed 1.00
Q)
17.10.04.03 Heat Exchanger, Darley Pump 1.00
Q)
17.10.12.02 Engine Compartment Light, LED, OEM Installed 1.00
Q)
17.10.15.01 Power Take Off (PTO), OEM Installed 1.00
Q)
17.11.01.01 Chassis Exhaust, Standard Modifications 1.00
R) 18.08.03 Wheel Chocks, Rubber, (2) Two, Connected by Rope, in Spare Compartment 1.00
Standard Pricing
This document contains a quote that is subject to change and is not a legally binding document.
$411,366.00Total Price
R) 18.10.10 PVC Flex Hard Suction Hose, 5" X 10', (1) One 2.00
R) 18.19 DOT Essential Kit 1.00
S) 19.01 2025 Freightliner Chassis estimate, M2-106 1.00
S) 19.01 Freightliner Chassis 1.00
S) 19.09 Freightliner - PTO Pump - Add 1.00
Z) NOR (1) NOR 5709, Gravity feed garden hose fitting from tank to pump panel with ball valve shutoff.1.00
Z) NOR (2) NOR 5712, MIV Electric master intake valve curbside, and manual butterfly valve street side.1.00
Z) NOR (3) NOR 5711, Whelen Arges remote controlled light on roof mounted on bracket to rear of lightbar 1.00
Z) NOR (4) NOR 2038, 6" NSTF x 5" NSTM Adapter for master intakes.2.00
Standard Pricing
2000 Gallon All-Poly® Series Tanker-
Pumper Specifications
Prepared for: City of Scandia Fire Department
Scandia, MN
Midwest Fire Rep: Craig Nekali
Date: 12/8/23
QMS-WIN-022 Rev Q
Notes:
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 2 Rev Q
Date Change Order # Op Number Description Rev
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 3 Rev Q
TABLE OF CONTENTS
Section 1: Booster tank ................................................................................................................................................. 8
1.00 “T” Tank with a Lifetime Warranty from Its Manufacturer .................................................................................................... 8
1.01 Tank Size ................................................................................................................................................................................. 8
1.01.02 All-Poly Series 2000 gallon ............................................................................................................................................ 8
1.02 Rear Fill Tower ........................................................................................................................................................................ 8
1.02.00 Center ............................................................................................................................................................................ 9
Section 2: Direct Fills and Tank Level ............................................................................................................................. 9
2.00 Street Side Direct Fill ............................................................................................................................................................... 9
2.00.04 Street Side 4” Storz ....................................................................................................................................................... 9
2.02 Tank Level Gauge .................................................................................................................................................................... 9
2.02.00.01 Tank Level Gauges automatic off at 10mph. ............................................................................................................ 9
2.02.08 One (1) Innovative Controls Soft Glo Series Water Tank Level Gauge .......................................................................... 9
2.03 Spanner Wrenches .................................................................................................................................................................. 9
2.03.02 Installed on the curb side rear panel. ............................................................................................................................ 9
2.04 Storz Wrenches ....................................................................................................................................................................... 9
2.04.01 Installed on the street side rear panel. ......................................................................................................................... 9
Section 3: Dump Valves and Chutes .............................................................................................................................. 9
3.00 Manual Dump Valves ............................................................................................................................................................ 10
3.00.01 Rear dump valve with 12” flip chute. .......................................................................................................................... 10
3.00.03 Street side rear dump valve with 36” telescoping chute. ........................................................................................... 10
3.00.04 Curb side rear dump valve with 36” telescoping chute. ............................................................................................. 10
Section 4: Portable Tank Carrier .................................................................................................................................. 10
4.00 Manual Tip-down Portable Tank Carrier ............................................................................................................................... 10
4.00.08 3000 gallons, curb side ................................................................................................................................................ 10
4.01 Manual Carrier Enclosure Option .......................................................................................................................................... 10
4.01.01 Portable Tank Carrier with front aluminum Tread -brite wind deflector. ................................................................ 10
4.06 Portable Tank ........................................................................................................................................................................ 10
4.06.08 3000 Gallons, Aluminum Frame, <color>, 159”x 29” .................................................................................................. 10
Section 5: Body and Components ................................................................................................................................ 10
5.00 Fenderettes ........................................................................................................................................................................... 11
5.00.01 Chrome Fenderettes .......................................................................................................................................................... 11
5.01 Rub Rail - Aluminum.............................................................................................................................................................. 11
5.02 Tow Eye ................................................................................................................................................................................. 11
5.03 Cradle .................................................................................................................................................................................... 11
Section 6: Body Compartments ................................................................................................................................... 12
6.00 Street Side Compartments .................................................................................................................................................... 12
6.00.01 Street Side Front Low Compartment........................................................................................................................... 12
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 4 Rev Q
6.01 Curb Side Compartments ...................................................................................................................................................... 12
6.01.01 Curb Side Front Low Compartment ............................................................................................................................. 12
6.02 Compartment Options .......................................................................................................................................................... 12
6.02.03 Adjustable shelf ........................................................................................................................................................... 12
Section 7: Running Boards, Catwalks, and Rear Step ................................................................................................... 13
7.00 Running Boards ..................................................................................................................................................................... 13
7.01 Catwalks ................................................................................................................................................................................ 13
7.02 Rear Step ............................................................................................................................................................................... 13
7.02.01 12” Deep Rear Step ..................................................................................................................................................... 13
Section 8: Grab Rails and Footsteps ............................................................................................................................. 13
8.00 Grabs Rails ............................................................................................................................................................................ 13
8.00.01 Rear Grab Rails ............................................................................................................................................................ 13
8.00.04 Front Grab Rail - Street side ........................................................................................................................................ 13
8.00.05 Front Grab Rail - Curb side .......................................................................................................................................... 13
8.01 Access Steps .......................................................................................................................................................................... 13
8.01.02 Front Folding Steps - Street side ................................................................................................................................. 14
8.01.03 Front Folding Steps - Curb side.................................................................................................................................... 14
8.01.04 Lower-Level Rear Steps ............................................................................................................................................... 14
8.02 Access Ladder ........................................................................................................................................................................ 14
8.02.02 Folding Hose Bed Access Ladder, Curb side ................................................................................................................ 14
Section 9: Electrical Equipment .......................................................................................................................................... 14
9.00 Multiplex Electrical System ................................................................................................................................................... 14
9.00.01 Innovative Controls Multiplex System .............................................................................................................................. 14
9.01 DOT Lighting Details ............................................................................................................................................................. 15
9.02 Lower-Level Rear Lighting ..................................................................................................................................................... 15
9.02.01 Quad cluster Taillight Package .................................................................................................................................... 15
9.03 Antenna................................................................................................................................................................................. 15
9.03.04 MWF Supplied Antenna Mounting Base ..................................................................................................................... 15
9.04 Camera System ..................................................................................................................................................................... 15
9.04.01 Rear view camera ........................................................................................................................................................ 15
9.06 Power Distribution Options ................................................................................................................................................... 15
9.06.05 Duplex Outlet - Shoreline ............................................................................................................................................ 15
9.06.06 12V Power Strip ........................................................................................................................................................... 16
Section 10: Emergency Siren and Lighting Equipment ................................................................................................... 16
10.00 Apparatus Control Center................................................................................................................................................. 16
10.01 Light Bar: ............................................................................................................................................................................... 16
10.01.01 Whelen model JE2NFPA Justice Series light bar ..................................................................................................... 16
10.01.05 Federal Signal Opticom Infrared System 794 ........................................................................................................... 16
10.02 Siren: ..................................................................................................................................................................................... 17
10.02.01 Whelen Siren .......................................................................................................................................................... 17
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 5 Rev Q
10.04 Lower-Level Lights ................................................................................................................................................................. 17
10.04.04 Front/Rear Whelen M6 Series LED .............................................................................................................................. 17
10.05 Intersection Lights ................................................................................................................................................................. 17
10.05.04 Intersection, Red, Chrome Bezel, M6 Series LED, Three (3) each side. .................................................................. 17
10.06 Upper-Level Side/Rear Warning Lights ............................................................................................................................ 17
10.06.08 Whelen M9V2 ......................................................................................................................................................... 17
10.07 Scene lights ...................................................................................................................................................................... 17
10.07.05 Automatic Reverse Scene Wiring ................................................................................................................................ 17
10.07.37 Fire Tech, HiViz LED Lighting, 46” Brow Light, Two (2) ................................................................................................ 17
10.09 Ground Lights ....................................................................................................................................................................... 18
10.09.02 Six (6) ground lights ................................................................................................................................................ 18
10.10 Accessory Lights ................................................................................................................................................................... 18
10.10.01 Wigwag Headlights ...................................................................................................................................................... 18
10.10.02 Whelen Traffic Advisor model TAL65 .......................................................................................................................... 18
10.10.06 Step Lights .................................................................................................................................................................. 18
10.10.07 Fire Tech, HiViz LED Lighting, Mini-brow Light ................................................................................................................ 18
10.10.???NOR Remote controlled light. Brand/Model/location TBD ....................................................................................... 19
Section 11: Painting, Lettering, Striping, and SignAGE ................................................................................................... 19
11.00 Painting process .................................................................................................................................................................... 19
11.00.01 Color Match Single Tone, <Color> ............................................................................................................................... 19
11.01 ID plate .................................................................................................................................................................................. 19
11.05 Reflective stripe ......................................................................................................................................................................... 20
11.05.03 Reflective tape inside chassis doors- Per NFPA 1901 standards any door designed to allow persons to enter, or
exit has a minimum of 96 square inches of retro-reflective material affixed to the inside of the door. ....................................... 20
11.05.05 (1x6x1) 6" wide <white> reflective stripe with a 1" wide <white> reflective stripe spaced approximately 1/2" above
and below. Stripe will be straight on the body and chassis. .......................................................................................................... 20
11.06 Rear Chevron ......................................................................................................................................................................... 20
11.06.05 Diamond Grade Pattern, Chevron 100% ................................................................................................................ 20
Section 12: Corrosion Protection and Mud Flaps ........................................................................................................... 20
12.00 Corrosion Protection ............................................................................................................................................................. 20
12.01 Mud Flaps ............................................................................................................................................................................. 21
Section 13: Pump and Plumbing .................................................................................................................................... 21
13.00 Pump House .......................................................................................................................................................................... 21
• Side Control Pump House ..................................................................................................................................................... 21
13.03 PTO Driven Pump .................................................................................................................................................................. 21
13.03.05 Darley LSP 1000 PTO Pump ......................................................................................................................................... 22
13.03.25 PTO Auto Governor Options ............................................................................................................................................. 23
13.03.25.01 Fire Research “Pump Boss 400 Series Auto Governor” .......................................................................................... 23
13.05 Primer Pump Option ............................................................................................................................................................. 23
13.05.01 Rotary Vane Primer Pump ........................................................................................................................................... 23
13.06 Suction Intakes ................................................................................................................................................................. 23
13.06.01 2 ½” Gated Intakes ................................................................................................................................................. 23
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 6 Rev Q
13.06.5712 Gated Master Intake Valves ................................................................................................................................... 23
13.07 Discharges ........................................................................................................................................................................ 23
13.07.01 Side Control Pump Panel Discharges ...................................................................................................................... 24
13.07.50 Installed Discharge Adapters ....................................................................................................................................... 24
*Must select an above discharge. Note the exact discharge operation number. .......................................................................... 24
13.08 Accessory Discharges ............................................................................................................................................................ 24
13.08.08 Plumbing for Deck Gun ..................................................................................................................................................... 24
13.08.08.01 Deck Gun Port ......................................................................................................................................................... 24
13.08.???NOR Gravity feed “garden hose” fitting with ball valve shutoff from tank to pump panel. ...................................... 24
13.09 Tank Fill/ Tank to Pump ........................................................................................................................................................ 24
13.09.01 Tank Fill Valve 2” ......................................................................................................................................................... 24
13.09.03 Tank to Pump 3” .......................................................................................................................................................... 24
13.11 Pump House Heat Control ......................................................................................................................................................... 24
13.11.02 Pump house heater 29,380 BTU/Hr. ........................................................................................................................... 24
13.11.04 Pump Compartment Heat Pan .................................................................................................................................... 24
13.12 Pump Certification ................................................................................................................................................................ 25
13.12.01 MWF Calibration ......................................................................................................................................................... 25
Section 14: Hose Trays, Pre-connects and Cross Lays ......................................................................................................... 25
14.08 Hose Cross Lay ...................................................................................................................................................................... 25
14.09 Pre-connected Cross Lays ...................................................................................................................................................... 25
14.10 Cross Lay Options .................................................................................................................................................................. 25
14.10.01 Cross Lay Divider ..................................................................................................................................................... 25
14.10.04 Cross Lay Vinyl Cover ................................................................................................................................................... 25
14.11 Hose Bed .................................................................................................................................................................................... 25
14.11.00 Hose Bed ..................................................................................................................................................................... 25
14.11.01 Hose Bed Divider .................................................................................................................................................... 25
14.11.02 Hose Bed cover ............................................................................................................................................................ 26
Section 15: Equipment Storage and Mounting .............................................................................................................. 26
15.00 Equipment Mounting Systems ......................................................................................................................................... 26
15.00.06 Trays located on the street side of the tank................................................................................................................ 26
Section 16: Hose Reel ........................................................................................................................................................ 26
16.00 Electric hose reel with Rubber Hose .......................................................................................................................................... 26
16.00.09 100' of 1" Rubber hose, below rear dump valve, behind rear panel. ......................................................................... 26
16.02 Hose Reel Options ................................................................................................................................................................. 26
16.02.01 Hose Reel Blowout ...................................................................................................................................................... 26
Section 17: Chassis Accessories .......................................................................................................................................... 26
17.01 Hub and Lug nut covers......................................................................................................................................................... 26
17.01.02 Single axle chassis. ....................................................................................................................................................... 26
17.03 Shoreline Connection, Kussmaul Pump Plus Series .......................................................................................................... 26
17.03.02 Pump Plus 1000 PLC system, 15-amp, manual plug-in beneath the street side chassis door. ............................... 26
17.08 Air Horns ............................................................................................................................................................................... 27
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 7 Rev Q
17.08.00 Two (2) Air Horns installed, one (1) on each side of the hood. ................................................................................... 27
17.10 Chassis Accessories ............................................................................................................................................................... 27
17.10.01 Tire Pressure Indicators ............................................................................................................................................... 27
17.10.04 Heat Exchanger ........................................................................................................................................................... 27
17.10.12 Engine Compartment Light, LED .................................................................................................................................. 27
17.10.15 Power Take Off (PTO) Installation ............................................................................................................................... 27
17.11 Chassis Exhaust ..................................................................................................................................................................... 27
17.11.01 Standard Chassis Exhaust Modifications ..................................................................................................................... 27
Section 18: Loose Equipment ............................................................................................................................................. 27
18.05 Adapters ........................................................................................................................................................................... 28
18.05.2038 6” NSTF x 5” MSTM Adapter for master intake, Qty (2) ......................................................................................... 28
18.08 Wheel Chocks ................................................................................................................................................................... 28
18.08.03 Two (2) Rubber Wheel Chocks, connected by rope, in spare compartment. ......................................................... 28
18.10 PVC Flexible Hard Suction Hoses ........................................................................................................................................... 28
18.10.10 5" x 10’, Qty (2)............................................................................................................................................................ 28
18.19 DOT Essential Kit ................................................................................................................................................................... 28
Section 19: Chassis ............................................................................................................................................................. 28
19.00 Midwest Fire supplied chassis per specification attached. Brief summary below: .................................................................... 28
SECTION 30: RESTRICTIONS................................................................................................................................................ 29
30.01 Maximum Height ....................................................................................................................................................................... 29
30.01.01 No Restrictions ............................................................................................................................................................ 29
30.02 Maximum Length ...................................................................................................................................................................... 29
30.02.01 No Restrictions ............................................................................................................................................................ 29
FINAL INSPECTION ............................................................................................................................................................. 29
DELIVERY ........................................................................................................................................................................... 29
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 8 Rev Q
SECTION 1: BOOSTER TANK
1.00 “T” Tank with a Lifetime Warranty from Its Manufacturer
The All-Poly Series features a polypropylene "T" style tank. The top of this tank may be used as a hose
bed, with optional dividers (see section 14). Hose beds stretch the full width and full length of the tank.
“T”-style tank fabricated from non-corrosive, stress-relieved virgin copolymer polypropylene
thermoplastic material. All exterior tank joints and seams are extrusion welded. All welds conform to
DVS and AWS standards. All joints, seams, and welds tested for integrity and leaks and are certified to
be free from defects. The top of the tank is white with a textured finish and is fitted with removable
lifting eyes designed with a 3-to-1 safety factor to facilitate easy removal.
The upper rear of the tank has a transverse internal bulkhead isolated from the water carrying portion
of the tank. This area may be used for wiring connections and for installing lights and grab handles. The
use of external blocks for mounting equipment will be kept to a minimum providing a pleasant
appearance. Wire tubes will be installed inside the tank, originating in the transverse bulkhead, and
terminating at the bottom of the tank. Wires for lights and equipment will not be visible from the
outside of the tank.
The material thickness will be dependent upon its function. The sides, top and ends will be 3/4" (.75)
thick. The baffles and fill tower will be 3/8 to 1/2" (.50) thick.
The transverse swash partitions extend approximately 4” off the floor to just under the cover. The
longitude swash partitions extend from the floor to the tank through the cover to allow for positive
welding and maximum integrity. All partitions are equipp ed with vent and air holes to permit
movement of air and water between compartments. The partitions are designed to provide maximum
water flow. All swash partitions interlock with one another and are welded to each other as well to the
walls of the tank. This baffling system will be fully compliant with NFPA and the DOT regulations.
There will be a sump located on the bottom of the tank with a ¾” drain valve at the lowest point. A 3”
minimum removable clean out plug is installed at the bottom rear and bottom front of the tank.
Tank fill couplings backed with flow deflectors to disperse the stream of water entering the tank, and
capable of withstanding sustained fill rates of up to 1,000 G.P.M. at 100 PSI maximum.
All auxiliary outlets and inlets must meet NFPA 1900 guidelines in effect at the time of manufacture.
1.01 Tank Size
1.01.02 All-Poly Series 2000 gallon
1.02 Rear Fill Tower
Tank has an overhead fill tower with lid, located at the rear of tank. Fill tower is constructed of 1/2"
polypropylene with minimum dimensions of 16" square. The tower has a 1/4" removable Poly screen
and a polypropylene hinged-type cover with a vent overflow. An internal overflow system is to be
inside in the tank and discharge behind the rear wheels. This allows air to enter the tank when
dumping water.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 9 Rev Q
1.02.00 Center
THE TANK WILL CARRY A LIFETIME WARRANTY FROM ITS MANUFACTURER
SECTION 2: DIRECT FILLS AND TANK LEVEL
2.00 Street Side Direct Fill
A fill directly into the tank at the rear of the apparatus is equipped with a valve, a 30-degree elbow,
bleeder valve, plug or cap holder with a tether chain.
2.00.04 Street Side 4” Storz
2.02 Tank Level Gauge
• Pressure transducer mounted on the outside of the tank in an easily accessible area. Sealed foam
tanks (if so equipped) will require zero pressure vacuum vents.
• Super bright LED display viewable from 180 degrees with a visual indication at multiple accurate
levels.
• Weather resistant connectors to connect to the digital display, the pressure transducer, and the
apparatus power. Additional displays are easily integrated and will receive data from the same
source as the Master Display; no additional transducers required.
• Tank level gauge indicates the liquid level on easy-to-read LED display.
2.02.00.01 Tank Level Gauges automatic off at 10mph.
The water and/or foam tank level gauges will automatically turn off when the apparatus’ speed
exceeds 10 mph and automatically turn on below 10 mph.
2.02.08 One (1) Innovative Controls Soft Glo Series Water Tank Level Gauge
2.02.08.01 Installed on the street side pump panel.
2.02.08.03 Installed at the rear street side.
2.02.08.11 Mini Dash, Installed on the center console.
2.03 Spanner Wrenches
One (1) adjustable hydrant wrench and two (2) spanner wrenches with holder.
2.03 .02 Installed on the curb side rear panel.
2.04 Storz Wrenches
Storz wrenches. Four (4) Storz spanner wrenches with holder
2.04.01 Installed on the street side rear panel .
SECTION 3: DUMP VALVES AND CHUTES
Newton 10" square stainless-steel Kwick-Dump Gate style (full flow) dump valves with stainless-steel
flip chutes and telescopic chutes. For improved water flow, the dump valve is attached directly to the
tank and not by use of a rear manifold system.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 10 Rev Q
3.00 Manual Dump Valves
Manual dump valves will have a locking control handle.
3.00.01 Rear dump valve with 12” flip chute.
3.00.01.03 Top handle
3.00.03 Street side rear dump valve with 36” telescoping chute.
3.00.04 Curb side rear dump valve with 36” telescoping chute .
SECTION 4: PORTABLE TANK CARRIER
4.00 Manual Tip-down Portable Tank Carrier
One (1) manual tip-down portable tank carrier for loading/unloading of a folding water tank located
above the catwalk and designed to fold down over the body side. When in the up position the tank,
carrier will be secured with heavy duty locking DeStaco latches. The tank carrier is constructed of 1
1/4" 14-gauge stainless-steel square tubing.
A red “Carrier down" flashing LED warning light visible to the driver will illuminate when the portable
tank carrier is not in the stowed position.
4.00.08 3000 gallons, curb side
4.01 Manual Carrier Enclosure Option
Portable tank carrier enclosure is enclosed on three sides and is equipped with two grab rails, except
for the wind deflector. If equipped, the wind deflector option is installed on the tank carrier towards
the front, and only has one grab rail.
4.01.01 Portable Tank Carrier with front aluminum Tread -brite wind deflector.
4.06 Portable Tank
The portable tank frame will be constructed with the requested material below. The tank liner is
constructed of nylon -coated material, 23 oz. side walls and a 30 oz. floor with handles installed in the
floor for ease of folding. All portable tanks will have two outlets.
4.06.08 3000 Gallons, Aluminum Frame, <color>, 159”x 29”
SECTION 5: BODY AND COMPONENTS
Body
• The body will be enclosed on all sides and incorporate closed wheel wells and finished storage
compartments.
• Stainless-steel corner guards to protect from damage on road and fire scene.
• Front lower vertical surface of body protected with aluminum Tread -brite.
Tank
• The tank is affixed to the cradle utilizing hat channel mounting brackets constructed of ¼” thick
stainless-steel. The channels are mounted beneath the center of the tank before and after the
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 11 Rev Q
cross members of the cradle. The channel is surrounding these members and is bolted directly
to the bottom of the tank thereby securing the tank to the cradle.
• This mounting system provides a free-floating connection of the tank to the cradle which allows
the chassis frame’s normal movement and twist to introduce no stress upon the tank or body.
Fenders
• Fenders will be integral with the side of the body.
• Fender wells are constructed with full circular copolymer polypropylene thermoplastic inner
liners for ease of cleaning and maintenance.
Materials
• The entire body is fabricated from non-corrosive, stress-relieved virgin copolymer
polypropylene thermoplastic material.
• All exterior body joints and seams are extrusion welded.
• All welds will conform to DVS and AWS standards.
• All joints, seams, and welds will be tested for integrity and are certified to be free from defects.
• All joints and are 100 percent welded inside and out; no skip welding is permitted.
THE BODY WILL CARRY A LIFETIME WARRANTY FROM ITS MANUFACTURER
5.00 Fenderettes
Fenderettes are installed on the wheel wells to prevent splash and enhance appearance. The
fenderettes extend approximately 1" beyond the body side and are designed to be replaced. All
fasteners will not be exposed to the exterior of the fenderettes or body.
5.00.01 Chrome Fenderettes
5.01 Rub Rail - Aluminum
The bottom edge of the entire apparatus will have a n aluminum rub-rail installed including the pump
house, and rear step. The rub-rail is replaceable, made from solid extruded aluminum and features a
reflective stripe at the rail center.
5.01.01 Red/White Stripe
5.02 Tow Eye
Attached to the rear of the chassis frame is a black powder coated steel support system that provides
extra strength to the rear body with integrated tow eyes.
5.03 Cradle
An all-aluminum cradle is engineered and constructed to connect the chassis frame with the copolymer
tank and body. The cradle is constructed using extruded aluminum tubing .25” thick and extruded
aluminum flats .375” thick. Cradle cross members are spaced to restrict unsupported portions of the
tank between cross members to a maximum of 550” squared. There are cushioned rubber e xtrusions
placed over all tank support areas to isolate the tank from the aluminum cradle.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 12 Rev Q
SECTION 6: BODY COMPARTMENTS
6.00 Street Side Compartments
• A sweep-out style compartment provided on the street side, integral to the body, constructed
using white copolymer material.
• Each compartment will have an anodized aluminum roll-up door, door activated LED
compartment lights, corrosion resistant vents, black Turtle Tile plastic dry decking, and floor
drains.
• Compartments at wheel height or below (located ahead or behind rear wheels) are 25” deep.
• Full height compartments have stepped depth: 12” above the wheel wells and 25” at wheel
height or below.
• Compartments located above the wheel wells are 12” deep.
6.00.01 Street Side Front Low Compartment
Compartment is located on the street side, ahead of the rear wheels. Approximate inside
dimensions are <>” wide by 32” tall by 25” deep.
6.01 Curb Side Compartments
• A sweep-out style compartment provided on the curb side, integral to the body, constructed
using white copolymer material.
• Each compartment will have an anodized aluminum roll-up door, door activated LED
compartment lights, corrosion resistant vents, black Turtle Tile plastic dry decking , and floor
drains.
• Compartments at wheel height or below (located ahead or behind rear wheels) are 25” deep.
• Full height compartments have stepped depth: 12” above the wheel wells and 25” at wheel
height or below.
• Compartments located above the wheel wells are 12” deep.
6.01.01 Curb Side Front Low Compartment
Compartment is located on the curb side, ahead of the rear wheels. Approximate inside
dimensions are <>” wide by 32” tall by 25” deep.
6.02 Compartment Options
6.02.03 Adjustable shelf
Adjustable shelf made of 3/16" smooth aluminum, installed with Unistrut adjustable brackets in
the compartments. Full height compartments have a deeper lower portion (about 24”), with a
shallower upper portion (about 12”) above frame rail height. Shelves will be made to the depth
of the compartment they are positioned in and full width of door opening unless specified
otherwise.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 13 Rev Q
6.02.03.13 Front, Street Side, Lower, Qty (1)
6.02.03.15 Front, Curb Side, Lower, Qty (1)
SECTION 7: RUNNING BOARDS, CATWALKS, AND REAR STEP
7.00 Running Boards
A 12” wide running board is located at the base of the pump house and is made from embossed
aluminum tread plate and includes a replaceable extruded aluminum rub rail.
7.01 Catwalks
Catwalks are located above the street and curb side compartments, made of embossed aluminum
tread plate, and bent at a 30-degree angle to provide a drip rail.
7.02 Rear Step
The rear step is NFPA compliant non-slip and made of embossed aluminum tread plate with a 7" tall
kick plate. Rounded polished aluminum castings installed on the corners of the step.
7.02.01 12” Deep Rear Step
SECTION 8: GRAB RAILS AND FOOTSTEPS
8.00 Grabs Rails
The grab rails are made of 1 ¼ " diameter extruded aluminum tubing with knurled finish and stanchion
brackets.
8.00.01 Rear Grab Rails
Vertical grab rail(s) provided at the rear.
8.00.01.02 One (1) Grab Rail, Street Side
8.00.04 Front Grab Rail - Street side
There is one (1) grab rail located on street side of tank in the upper front corner for ease of
loading and unloading hose cross lays.
8.00.04.01 Front Grab Rail - Street side
8.00.05 Front Grab Rail - Curb side
There is one (1) grab rail located on curb side of tank in the upper front corner of tank for ease
of loading and unloading hose cross lays.
8.00.05.01 Front Grab Rail - Curb side
8.01 Access Steps
As per NFPA 1901 standards, all steps are a minimum of 35" square.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 14 Rev Q
8.01.02 Front Folding Steps - Street side
Large illuminated folding steps are provided at the front on the street side, for access to the
catwalk area. The steps are a minimum of 35" square .
8.01.02.01 Chrome Plated, Quantity one (1)
8.01.03 Front Folding Steps - Curb side
Large illuminated folding steps provided at the front on the curb side, for access to the catwalk
area. The steps are a minimum of 35" square.
8.01.03.01 Chrome Plated, Quantity one (1)
8.01.04 Lower-Level Rear Steps
Large illuminated steps provided at the rear for access to the catwalk area. The steps are a
minimum of 35" square with polished kick-plates.
8.01.04.02 Chrome Plated, Folding Step, One (1), Street Side
8.02 Access Ladder
8.02.02 Folding Hose Bed Access L adder, Curb side
A folding hose bed ladder installed on the rear curb side of the apparatus. The ladder folds
down below the rear step and is accessible from the ground. The heavy duty constructed all
aluminum ladder will have gas assisting struts with cast aluminum steps approximately 14”
apart.
SECTION 9: ELECTRICAL EQUIPMENT
9.00 Multiplex Electrical System
9.00.01 Innovative Controls Multiplex System
• The apparatus is equipped with a battery disconnect “Master Switch” mounted inside the
chassis cab.
• Control Display
The apparatus is equipped with a full color LCD display, with push buttons and touch screen
capability with J1939 CAN Bus connections and video inputs. It is bonded for direct sunlight
viewing, sealed against harsh weather conditions, and mounted flush in the center console.
• Push Button Switch Modules
The apparatus is equipped with the appropriate quantity of push button switch modules for
enhanced device activation. Individual switches are backlit with symbol labels. Switch panels
are sealed against harsh weather conditions and have LED indicators. E ach switch position’s
back light may be individually controlled allowing for the specific switch position to be used as
an indicator.
• The multiplex system includes the functions of the Vehicle Data Recorder and Seat Belt
Monitor.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 15 Rev Q
• The multiplex system utilizes a Controller Area Network (J1939) protocol to provide multiplexed
control signals for "real time" operation. The system consists of a main control module and the
appropriate combination of additional module(s), Switch Input Module(s), and other I/O
modules as required for each apparatus’ application.
9.01 DOT Lighting Details
• A total of nine (9) LED clearance lights and seven (7) red LED lights installed at the rear.
• Two (2) amber LED lights are installed on the front street and curb sides.
• Reflectors are installed per DOT specifications.
• A red warning light visible to the driver in the chassis cab that illuminates when a compartment
door is ajar/open.
• An illuminated license plate bracket installed at rear.
9.02 Lower-Level Rear Lighting
9.02.01 Quad cluster Taillight Package
Two (2) LED Quad-Cluster combination include: red LED stop/tail, clear LED backup light, amber
LED arrow type turn signal, and LED warning light, installed at the rear. Light assemblies
provided in a four-light housing.
9.02.01.02 Whelen M6 Series Quad-Cluster, Chrome Bezel
9.03 Antenna
9.03.04 MWF Supplied Antenna Mounting Base
Midwest Fire will supply and install an antenna mounting base and coax cable only. The
customer will be responsible for supplying and installing the antenna. The antenna base will be
installed on the chassis roof behind the lightbar. Cable will be labeled and tied up inside the
center console if a radio is not mounted. If a radio is mounted the antenna will be crimped and
attached to the radio.
9.04 Camera System
9.04.01 Rear view camera
One (1) rear view camera system installed. Camera system includes a colored wide-angle rear
mounted camera and 7” monitor mounted in the center of the vehicle’s dashboard unless
specified otherwise. Automatically activated when truck is put in reverse.
9.04.01.02 Rear View Camera
9.06 Power Distribution Options
9.06.05 Duplex Outlet - Shoreline
Shoreline connected 110v duplex outlet installed in the upper front sill of the compartment
unless specified otherwise.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 16 Rev Q
9.06.05.09 Rear of Center Console, Facing Rear
9.06.06 12V Power Strip
A 12V Battery Power, 6 position overload/short protected terminal strip will be installed in the
upper front sill of the compartment unless specified otherwise.
9.06.06.09 Inside Center Console, Wired to Chassis Battery
9.06.06.10 Inside Center Console, Wired to Master Switch
SECTION 10: EMERGENCY SIREN AND LIGHTING EQUIPMENT
10.00 Apparatus Control Center
All emergency lighting, options, and accessories are controlled at a master control center in the cab.
The apparatus control center:
• Controls all warning lights and scene lights.
• Includes an "Open Door" and other optional indicator lights.
• UV700 Multiplex display – If equipped.
• Controls other optional functions if equipped. (I.E. Electric Dump Valves, Pump Shift)
• Mounted Electronics, Sirens, and Radios – If equipped.
• Features lighted identification plates on a non-glare panel face that clearly identify each switch
and its function.
• Removable lid on console for maintenance and adding additional items.
• Control Centers will require that there be no seat in between the driver and passenger seats.
All warning packages are fully NFPA compliant and certified by the lighting component manufacturer to
meet all requirements.
10.00.01 Center Console for Freightliner Chassis
10.01 Light Bar:
The light bar is mounted on the cab roof.
10.01.01 Whelen model JE2NFPA Justice Series light bar
Whelen model Justice Series, Super-LED low-profile, 56” long. Covers front and front side
zones. The light bar has four (4) linear corner modules with nine (9) Super-LED light heads per
module, and six (6) CON3 modules with three (3) CON3 Super -LED light heads per module.
10.01.01.01 Whelen JE2NPFA Justice Series, Red
10.01.05 Federal Signal Opticom Infrared System 794
Federal Signal Opticom Infrared System is installed on top of the chassis roof. The Opticom
Model 794-AH LED Emitter is a compact, lightweight, weather-resistant encoded signal device
intended for use on priority vehicles. The model 794-AH emitter consists of an infrared LED
array with an integral power supply and the required cables.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 17 Rev Q
10.02 Siren:
10.02.01 Whelen Siren
Whelen Siren 200-watt, six (6) function Class A electronic siren, mounted in the chassis cab in a
location convenient to the driver. The electronic siren includes full function, 17 Scan-Lock siren
tones, and hard-wired microphone. The siren control is lighted for easy night operation. Cast
aluminum speaker available with three (3) siren mounting locations.
10.02.01.02 Whelen 295SLSA1 siren w/ speaker flush mounted street side
10.04 Lower-Level Lights
10.04.04 Front/Rear Whelen M6 Series LED
Whelen M6 series LED lights. Front lights will be mounted on the grill of the chassis. Rear lights
will be in taillight cluster. Lights will have clear lenses.
10.04.04.02 Front/Rear Flashers, Red, Chrome Bezel, Two (2) mounted on grill of
chassis, Two (2) mounted on rear of body, Four (4) Total
10.05 Intersection Lights
All lights mounted 18” above the ground, and no higher than 60”. One (1) positioned as far forward as
possible, and one (1) positioned as close to the rear of the truck. *With three (3) lights one (1)
positioned behind the cab, but in front of the rear wheels. Lights will have clear lenses.*If there is a
front bumper extension the lights will be mounted on the extension not the side of the hood.
10.05.04 Intersection, Red, Chrome Bezel, M6 Series LED, Three (3) each side.
10.06 Upper-Level Side/Rear Warning Lights
10.06.08 Whelen M9V2
Whelen M9V2 Series Combination LED Scene Light/Flasher. Lights will have clear lenses.
10.06.08.02 Side/Rear, Scene/Flashers, Red, Chrome Bezel, M9V2 Series, Two (2)
each side of the tank in the front and rear upper corners, with two (2)
on the rear of apparatus in the upper corners. (Six (6) Total)
10.07 Scene lights
Scene Lights are controlled from the control center located in the chassis cab and a One Touch switch
pack located on the pump panel.
10.07.05 Automatic Reverse Scene Wiring
Rear scene lights will be wired to illuminate when chassis is placed in reverse.
10.07.37 Fire Tech, HiViz LED Lighting, 46” Brow Light , Two (2)
There are two (2) 46" wide FireTech HiViz LED brow lights mounted in the upper center of the -
tank, one (1) on the street side and one (1) on the curb side.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 18 Rev Q
10.07.37.01 White Housings
10.09 Ground Lights
10.09.02 Six (6) ground lights
There are six (6) LED ground lights installed to illuminate the area below the apparatus. Two (2)
lights are installed on street and curb side below the chassis steps, two (2) lights are installed
on street and curb side below the pumphouse step, and two (2) lights are installed on street
and curb side below the rear step area. Grounds lights will be activated when parking brake is
applied.
10.10 Accessory Lights
10.10.01 Wigwag Headlights
Headlights have alternating headlight (wigwag) warning capability in low beam only. Wigwag is
activated by a switch in the cab.
10.10.01.01 Chassis OEM Installed
10.10.02 Whelen Traffic Advisor model TAL65
There is one (1) Whelen Traffic Advisor model TAL65, supplied. Traffic Advisor is 36” wide, with
six (6) LED lamps mounted on the upper rear of the tank and activated by a control head in the
cab.
10.10.02.03 Recessed poly-box built into the rear of tank.
10.10.06 Step Lights
10.10.06.01 Four (4) Step Lights
There are four (4) LED step lights installed to illuminate the chassis steps. Two (2) lights
are installed on the street and curb side below the chassis doors, one (1) per step. Two
(2) lights are installed on the street and curb side below the top chassis step to
illuminate the bottom step, one (1) per step. Step lights will be activated when parking
brake is applied.
10.10.07 Fire Tech, H iViz LED Lighting, Mini-brow Light
Two (2) Fire Tech, HiViz LED Lighting, one (1) Mini-brow Light is mounted on top of the chassis
cab, as far forward as possible and one (1) Mini-brow light is mounted on rear panel of truck,
centered and as high up as practical. Activated by switches in the control center.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 19 Rev Q
10.10.07.01 Fire Tech Combination 10-degree spot and 60-degree flood optic
configuration. 9 LED Mini Brow. 12" length. FT-MB-9-FT, White Housing.
Qty (2)
10.10.???NOR Remote controlled light. Brand/Model/location TBD
SECTION 11: PAINTING, LETTERING, STRIPING, AND SIGNAGE
11.00 Painting process
The entire tank, body, and components will be washed, sanded, prepped for primer, cleaned, and
primed with PPG urethane primer filler. The body will be hand sanded and color match painted using a
PPG Deltron base coat/clear coat paint. After paint is applied and properly cured the apparatus will be
color sanded and buffed to a high gloss. The paint process is approved by PPG.
11.00.01 Color Match Single Tone, <Color>
11.00.01.02 Color Matched, 1900 - 2000 gallon
10-YEAR WARRANTY ON PAINTED BODY PARTS
11.01 ID plate
There is a permanent plate located in the chassis cab with the following information:
Quantity and type of fluids used in the vehicle. This plate includes:
• Engine oil, quantity.
• Engine coolant, quantity.
• Chassis transmission fluid, quantity.
• Pump transmission fluid, quantity.
• Drive axle lubrication fluid, quantity.
• Air conditioning refrigerant, quantity.
• Air conditioning lubrication oil, quantity.
• Power steering fluid, quantity.
• Front and rear cold tire pressure.
• Number of personnel the vehicle is designed to carry located in an area visible to the driver.
• Height and length of the vehicle in feet and inches.
• Gross vehicle weight rating (GVWR) in pounds.
• A safety sign FAMA07, which warns of the importance of seat belt use, shall be visible from
each seat that is intended to be occupied while the vehicle is in motion.
• A safety sign FAMA10, which warns of the need to secure items in the cab, shall be visible inside
the cab.
• A safety sign FAMA15, which warns not to wear helmets while the vehicle is in motion, shall be
visible from each seat that is intended to be occupied while the vehicle is in motion.
• A safety sign FAMA24, which warns personnel not to ride on the vehicle, shall be located at the
rear step areas and at any cross walkways.
• Do Not Move Apparatus Light
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 20 Rev Q
o A red flashing light located in the chassis cab. The light shall be illuminated
automatically whenever the vehicles parking brake is not fully engaged and any of the
following conditions exist:
• Any passenger or equipment compartment door is not closed.
• Any ladder or equipment rack is not in the stowed position.
• Stabilizer system is not in its stowed position.
• Powered light tower is not stowed.
• Any other device permanently attached to the apparatus is open, extended, or
deployed in a manner that is likely to cause damage to the apparatus if the
apparatus is moved.
11.05 Reflective stripe
The apparatus body and chassis will have a reflective stripe on each side and the front bumper per
NFPA 1901 standards.
*Sales Note: Stock colors are White, Black, Red, Blue, Gold. Stock widths are 1”, 4”, 6”. Different
colors or sizes will require a NOR.
11.05.03 Reflective tape inside chassis doors - Per NFPA 1901 standards any door
designed to allow persons to enter, or exit has a minimum of 96 square inches
of retro-reflective material affixed to the inside of the door.
11.05.03.01 Single Cab
11.05.05 (1x6x1) 6" wide <white> reflective stripe with a 1" wide <white> reflective
stripe spaced approximately 1/2" above and below. Stripe will be straight on
the body and chassis.
11.05.05.01 Single Axle
11.06 Rear Chevron
11.06.05 Diamond Grade Pattern, Chevron 100%
Per NFPA 1901 standards, 100 percent of the rear will include red and fluorescent yellow
diamond grade pattern chevron retro-reflective stripe installed, with each stripe a minimum of
6” wide.
SECTION 12: CORROSION PROTECTION AND MUD FLAPS
12.00 Corrosion Protection
The All-Poly Series body has several features which prevent corrosion.
• All fasteners are stainless-steel where applicable.
• All contacts of dissimilar metals are insulated with 3M products to prevent galvanic corrosion.
• Rub rails are Type II bright dip anodized.
• Tow rings are powder coated steel.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 21 Rev Q
• The Poly body material eliminates the need for undercoating and sprayed on coating inside
storage lockers.
• The Poly body material is non-corrosive and is frequently used for storing acids.
• The Poly body material eliminates many possibilities of dissimilar metal contact caused by
galvanic reaction.
12.01 Mud Flaps
There are two mud flaps installed behind the rear wheels.
• The mud flaps are ¼ inch thick black rubber.
• The bottom of the mudflaps are fitted with chrome weights.
SECTION 13: PUMP AND PLUMBING
13.00 Pump House
• Side Control Pump House
The pump compartment features:
• The superstructure frame is made from .125” wall X 2.00” square type aluminum tubing.
• The front and a portion of the rear of the pump compartment is made from aluminum tread
plate sheets to enclose the perimeter of the water pump.
• There will be two (2) horizontal grab rails provided, one on each side, above the pump control
panels.
• The street and curb sides of the pump compartment are equipped with side running boards.
The running boards extend along the width of the pump compartment from the rear of the
chassis cab to the forward end of the body module.
• Pump side panels are covered with black protective material.
• Running boards include extruded aluminum rub rail extending the length of the running boards.
• The step surfaces comply to applicable sections of NFPA 1901 requirements.
• A safety sign FAMA25, which warns of the need for training prior to operating the apparatus,
shall be located on the pump operator’s panel.
• A rubber pump compartment seal provided between the rear of the pumphouse and the body.
13.03 PTO Driven Pump
PTO Pumps have the following standard features:
• All PTO driven pumps have pump-and-roll capability.
• Helical design and precision-cut gears to reduce noise and minimize wear.
• Double seal ring design solid bronze impeller
• Stainless-steel pump shaft
• Maintenance free mechanical seal
• The street and curb side pump panels and access doors are constructed entirely of aluminum
and be covered with black protective material.
• The pump compartment has full width vertically hinged access doors located on the upper
portion of the street and curb side pump compartment.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 22 Rev Q
• A latch is furnished to hold the doors closed and have a retainer attached to prevent over
extension of the opened door.
• The pump operator panels are to be completely "bolted" or hinged in place for ease of removal.
• A full panel width LED light hood is provided to illuminate the street and curb side pump panels.
• A service light is provided to illuminate the interior of the pump compartment. Lights are
controlled by the operator's panel light switch.
• The operator's panel include the following gauges:
• 2 1/2" 400# liquid filled stainless-steel individual discharge pressure gauges and control
handles.
• One (1) 3 1/2” Master Discharge Gauge and one (1) 3 1/2” Master Pump intake gauge.
• Color-coded pump panel identification labels are provided for all gauges, controls, connections,
switches, inlets, and outlets.
• The intakes have a removable strainer provided and chrome plated caps.
• Pump shift is electric operated and incorporates standard automotive shifting mechanism for
ease of maintenance.
• The pump engage switch is mounted in the cab Multiplex screen and on the pump panel’s
Smart Touch Switch Module. Identified as "Engage Pump". The pump engage indicator includes
a light to show when the PTO has been engaged and is OK to Pump.
• A test plate shall be provided at the pump operator's panel that gives the rated discharges and
pressures together with the speed of the engine as determined by the certification test for each
unit, the position of the parallel/series pump as used, and the governed speed of the engine as
stated by the engine manufacturer on a certified brake horsepower curve.
• The test label shall be completely stamped with all information at the factory and attached to
the vehicle prior to shipping.
• A master manifold type drain valve is provided with all pump drains connected to it and
operate from the pump operators panel, so the entire pump system may be drained by a single
control.
• A master manifold type drain valve is provided with all pump drains connected to it and
operate from the pump operators panel, so the entire pump system may be drained by a single
control.
• Per NFPA 1901 standards there shall be pump system test ports mounted on the pump panel.
• All discharges and pre-connects with a 1 ½” or larger valve, per NFPA 1901 standards, shall have
drains or bleeder valves, having a minimum ¾” pipe thread connection, for bleeding off
pressure from the hose connection to the outlet.
• Per NFPA 1901 standards there shall be a suction relief valve installed on the intake sides of the
pump, terminated with a NST male threads.
• The pump will have at minimum of two (2) sacrificial anodes included.
ENGINEERING NOTE FOR PUMP MODULES: ORDER PUMP MODULES WITH A CAP FLANGED IF THE PUMP HAS A REMOTE
MOUNT CONTROLLER ( FRONT SWEEPS, MONITOR, ETC.)
13.03.05 Darley LSP 1000 PTO Pump
All the plumbing and/or piping in the pump compartment will be constructed of 304 stainless-
steel or flexible piping for long life. All NPT pipe thread connections larger than ¾” connections
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 23 Rev Q
are avoided in the construction of the plumbing system. The following valves shall have groove
connection: rear discharge, tank fill, all 2” and 2-½” pre-connect valves.
Pump Ratings:
1000 GPM @ 150 PSI
700 GPM @ 200 PSI
500 GPM @ 250 PSI
13.03.05.01 Darley LSP 1000 PTO, Side Control, 36” Pumphouse
13.03.25 PTO Auto Governor Options
13.03.25.01 Fire Research “Pump Boss 400 Series Auto Governor”
• Features:
o Discharge pressure in PSI.
o Pump adjustment back idle.
o Engine monitoring of oil pressure, water temperature, battery voltage, and
engine RPM.
o Preset function for instant and reliable operation.
o Overheat pump protection system.
13.05 Primer Pump Option
13.05.01 Rotary Vane Primer Pump
The rotary vane primer is a 12-volt electric, positive displacement, rotary vane type, oil-less
primer for 20' to 30' suction lifts. Priming system includes a bronze push -pull valve with electric
switch.
13.06 Suction Intakes
On all pumps, an intake suction relief shall be provided per NFPA 1901 standards. It will be terminated
with a 2 ½” NST male adapter.
13.06.01 2 ½” Gated Intakes
Each intake consists of a 2 ½ " NST female chrome plated swivel intake located on the pump
panel. The intake has a 2 ½ " valve, swivel adapter with screen, chrome plated plug and chain.
13.06.01.01 One (1) intake, street side
13.06.5712 Gated Master Intake Valves
The Master Intake Valves (MIV) will be installed inside the pump house. Controls to be
mounted on the pump panel, with an indicator light showing status of the MIV.
13.06.5712.01 Street Side MIV, Manual
13.06.5712.02 Curb Side MIV, Electric
13.07 Discharges
Discharges include:
• Tee Handle Control
• 2 ½” 400 PSI Liquid Filled Stainless Pressure Gauge
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 24 Rev Q
• 30 Degree Elbow, cap and chain
➢ Max two (2) discharges per side on the pump panels.
➢ With two (2) discharges on the curb side, one (1) curb side discharge must be a 2 ½”
discharge.
13.07.01 Side Control Pump Panel Discharges
13.07.01.02 Two (2) 2 ½” Discharge, Street Side
13.07.01.03 One (1) 2 ½” Discharge, Curb Side
13.07.01.08 One (1) 4” Discharge, Curb Side, Electric
13.07.50 Installed Discharge Adapters
*Must select an above discharge. Note the exact discharge operation number.
13.07.50.09 4” NSTF swivel rocker lug x 4” Storz lock and Cap, 30-Degree Elbow Installed
on 13.07.01.08
13.08 Accessory Discharges
13.08.08 Plumbing for Deck Gun
13.08.08.01 Deck Gun Port
Port left accessible for future install of deck gun plumbing. A gauge, valve, and handle are not
provided.
13.08.???NOR Gravity feed “garden hose” fitting with ball valve shutoff from tank to pump
panel.
13.09 Tank Fill/ Tank to Pump
13.09.01 Tank Fill Valve 2”
A 2" tank fill/pump re-circulating line provided from the pump to the water tank, with a 2"
valve and 2" high-pressure flexible hose.
13.09.01.01 2” Tank Fill Valve, Side Control
13.09.03 Tank to Pump 3”
A 3” tank to pump line provided from the water tank to the pump, with a 3” valve and tee
handle controls, and 4” plumbing with flexible connection with check valve.
13.09.03.01 Manual Controls, Side Control
13.11 Pump House Heat Control
13.11.02 Pump house heater 29,380 BTU/Hr.
A 29,380 BTU/HR pump house heater is installed in the pumphouse, controlled by a switch on
the pump panel.
13.11.04 Pump Compartment Heat Pan
A removable aluminum heat pan installed below the pump compartment.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 25 Rev Q
13.12 Pump Certification
13.12.01 MWF Calibration
The pump test shall be certified by a Midwest Fire representative.
SECTION 14: HOSE TRAYS, PRE -CONNECTS AND CROSS LAYS
14.08 Hose Cross Lay
• The hose cross lay provides an area for pre-connected hose cross lays and/or hose storage.
• The cross lay is constructed of a 1” thick polypropylene/polyethylene floor designed to provide
drainage and ventilation to the cross lay area.
• Front and rear are constructed of 1/8” aluminum.
14.08.01 Hose cross lay above Side Control Pump
14.09 Pre-connected Cross Lays
• Cross lay is pre-connected via NST swivel male gated with a ball valve.
• Pre-connect has a 2 ½ " 400psi liquid filled stainless-steel individual pressure gauge and control
handle. All cross lay pre-connects are foam capable (if equipped) except for LRR.
14.09.02 Two (2) 1 ½ " NST male pre-connects, 2” valve
14.10 Cross Lay Options
14.10.01 Cross Lay Divider
Hose cross lay is equipped with adjustable divider constructed of 3/16” aluminum.
14.10.01.02 Two (2) Cross Lay Dividers
14.10.04 Cross Lay Vinyl Cover
Heavy-duty flame-retardant vinyl cover with mesh ends is supplied and custom fitted to the
apparatus cross lay. The cover is attached with shock cord to retain the cover during travel as
required by NFPA.
14.10.04.01 Black Cross lay Cover
14.11 Hose Bed
14.11.00 Hose Bed
Hose bed runs the full length and width of the tank. The floor of the hose bed is grooved to
allow the loaded hose to drain and provide ventilation. The floor is fabricated from UV stable
white polypropylene with inverted T slot are machined into the floor at three points to
accommodate adjustable hose dividers.
14.11.00.01 10” Tall Hose Bed Walls
14.11.01 Hose Bed Divider
The hose bed has adjustable divider made from copolymer. The rear of the divider will have slot
cut in that can be used for a hand grip.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 26 Rev Q
14.11.01.02 Two (2) dividers
14.11.02 Hose Bed cover
Heavy-duty vinyl hose bed cover is attached across the front of the hose bed with a rail and
bead system to prevent wind from getting under the cover, with a flap to cover the back of the
hose bed and has a quick release elastic rope to retain the hose in the bed during travel as
required by NFPA.
14.11.02.01 Black Hose Bed Cover for 1500 – 2000
SECTION 15: EQUIPMENT STORAGE AND MOUNTING
15.00 Equipment Mounting Systems
15.00.06 Trays located on the street side of the tank.
15.00.06.03 Two (2) Trays for 5”-6” Suction Hose.
SECTION 16: HOSE REEL
16.00 Electric hose reel with Rubber Hose
One (1) electric rewind hose reel with hose rollers, gated with a 1” valve and supplied with rubber
hose. Each hose reel comes equipped with one (1) button located close to the reel in an accessible
location.
16.00.09 100' of 1" Rubber hose, below rear dump valve, behind rear panel.
16.02 Hose Reel Options
16.02.01 Hose Reel Blowout
One (1) quarter turn style valve hooked up to the chassis air system for use in expelling the
water from the hose reel plumbing.
SECTION 17: CHASSIS ACCESSORIES
17.01 Hub and Lug nut covers
Stainless-steel hub and lug nut covers are installed on front and rear aluminum wheels
17.01.02 Single axle chassis.
17.01.02.02 Chassis OEM Install
17.03 Shoreline Connection, Kussmaul Pump Plus Series
One (1) Kussmaul Pump Plus, air and battery conditioner system installed.
17.03.02 Pump Plus 1000 PLC system, 15-amp, manual plug-in beneath the street side
chassis door.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 27 Rev Q
17.08 Air Horns
Two (2) Stutter Tone air horns mounted. Steering wheel horn switch will control the air horns unless
specified otherwise.
17.08.00 Two (2) Air Horns installed , one (1) on each side of the hood.
17.08.00.03 Chassis OEM Installed Lanyard Controls. Omits previously stated
“Steering wheel” control.
17.10 Chassis Accessories
17.10.01 Tire Pressure Indicators
Tire pressure indicators installed to allow for inspection of pressure at the tire.
17.10.01.03 Tire Pressure Indicator, Chassis OEM Installed
17.10.04 Heat Exchanger
A Heat exchanger permits the use of water from the pump to cool the engine. Cooling is done
without mixing the engine antifreeze and the pump water.
17.10.04.03 Darley Pump
17.10.12 Engine Compartment Light, LED
A LED light will be installed in the engine compartment. The light will have at least 250 lumens
and activated when the hood is open, and deactivated when the hood is shut.
17.10.12.02 Chassis OEM Install
17.10.15 Power Take Off (PTO) Installation
One (1) PTO will be installed for the pump specified in section 13.03.
17.10.15.01 Chassis OEM Install
17.11 Chassis Exhaust
17.11.01 Standard Chassis Exhaust Modifications
Chassis exhaust is modified to exit passenger side ahead of the rear wheels and vent outwards
from the edge of the body. A heat shield will be fabricated from aluminum and installed
between the body and the exhaust pipe. OEM supplied exhaust tip will be used when
applicable.
17.11.01.01 Freightliner Exhaust Modifications
SECTION 18: LOOSE EQUIPMENT
Loose equipment required by NFPA not listed will be supplied by customer after delivery of the apparatus
prior to being put in service.
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 28 Rev Q
18.05 Adapters
18.05.2038 6” NSTF x 5” MSTM Adapter for master intake, Qty (2)
18.08 Wheel Chocks
18.08.03 Two (2) Rubber Wheel Chocks, connected by rope, in spare compartment .
18.10 PVC Flexible Hard Suction Hoses
18.10.10 5" x 10’, Qty (2)
18.19 DOT Essential Kit
DOT Essential OSHA ANSI Compliant Kit includes:
• 21" Duffel Bag,
• DOT Compliant UL LISTED Fire Extinguisher 1.5 lb 5BC Fire Extinguisher. Plastic mounting brackets are
included with all fire extinguishers (mounted by FD).
• DOT Compliant Set of 3 DOT Triangles in the plastic box.
• Set of 12 Electrical Fuses- 6 regular/6 Mini (spare fuses supplied by FD).
• Bulk ANSI A Weatherproof First Aid Kit with Plastic Case
o (16) 1" x 3" Plastic Bandages, (1) 1/2" x 5 yd First Aid Tape, (10) Triple Antibiotic Ointment Packets, (10)
BZK Antiseptic Towelettes, (1) CPR Mask w/ One Way Valve, (1) 4" x 4" Burn Dressing, (10) First Aid/Burn
Cream Packets, 0.9 g, (1) 4" x 5" Cold Compress, (2) Sterile Eye Pads, (1) Eyewash, 1 oz, (6) Hand Sanitizer
Packets, 0.9 g, (4) Nitrile Exam Gloves, (1) 2" Conforming Gauze Roll, (1) Scissors, (2) 3" x 3" Gauze
Dressing Pads, (2) 5" x 9" Trauma Pads, (1) 40" x 40" x 56" Triangular Sling/Bandage.
SECTION 19: CHASSIS
19.00 Midwest Fire supplied chassis per specification attached. Brief summary below:
Chassis Summary
Manufacturer Freightliner Cab Type (Reg, Ext, Crew) Regular
Model M2 106 Cab to Axle (in.) 150”
Engine Manufacturer Cummins Wheelbase (in.)
Engine Model L9 Front Axle Rating (Lbs.) 14600
Horsepower 360 Rear Axle Rating (Lbs.) 31000
Transmission Make Allison Paint Color Code TBD
Transmission Model EVS 3000 Two-Tone Scheme TBD
LED Headlights Yes Auxiliary Brake Exhaust
Electric Windows Yes Rear Differential Locks Single Full
Electric Locks Yes Air Brake System Drum Brakes
Foot Pedal MPH 60 mph Cruise Control MPH 60 mph
Scandia MN specificaton 12-8-23 (1)
Save Date: 12/15/2023 9:18 AM Customer Initials ______
Print Date: 12/15/2023 9:18 AM 29 Rev Q
SECTION 30: RESTRICTIONS
30.01 Maximum Height
30.01.01 No Restrictions
30.02 Maximum Length
30.02.01 No Restrictions
FINAL INSPECTION
The department will take physical possession of the truck and will receive all training on the operation
of the truck at the Midwest Fire facility in Luverne, Minnesota during the final inspection/ delivery day.
DELIVERY
Transportation of the apparatus post final inspection is the responsibility of the department .