Loading...
5.a 5 Appendix D - Woolford Generation Interconnection Application FormNorthern States Power Company, a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 102 APPENDIX B: Generation Interconnection Application Form WHO SHOULD FILE THIS APPLICATION: Anyone expressing interest to install generation which will interconnect with Xcel Energy (Local electric utility). This application should be completed and returned to the Generation Interconnection Coordinator, in order to begin processing the request. INFORMATION: This application is used by Xcel Energy to perform a preliminary interconnection review. The Applicant shall complete as much of the form as possible. The fields in BOLD are required to be completed to the best of the Applicant's ability. The Applicant will be contacted if additional information is required. The response may take up to 15 business days after receipt of all the required information. COST: A payment to cover the application fee shall be included with this application. The application fee amount is outlined in the "State of Minnesota Interconnection Process for Distributed Generation Systems". OWNER/APPLICANT Company / Applicant's Name: MSC-Scandia0l, LLC Representative: Charlie Nickoloff Phone Number: 612-709-8064 FAX Number: n/a Title: Vice President Mailing Address' 345 St Peter St - Suite 1600, St Paul MN 55102 Email Address: canickoloff@mnsolarconnection.com LOCATION OF GENERATION SYSTEM INTERCONNECTION Street Address, legal description or GPS coordinates: 23485 Manning Trail N, Scandia MN 55073 PROJECT DESIGN / ENGINEERING (if applicable) Company: Westwood Professional Services Representative: Jack Hays I Phone: 952-697-5703 FAX Number: n/a Mailing Address: 7699 Anagram Dr, Eden Prairie MN 55344 Email Address:jack.hays@westwoodps.com ELECTRICAL CONTRACTOR (if applicable) Company: TBD Representative: TBD Phone: TBD FAX Number: TBD Mailing Address: TBD Email Address: TBD (Continued on Sheet No. 10-103) Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company Docket No. E002/GR-05-1428 Order Date: 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 102.doc Northern States Power Company, a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 103 APPENDIX B: Generation Interconnection Application Form (Continued) GENERATOR Manufacturer: ChlntPower Systems Model: 5okW Type (Synchronous Induction, Inverter, etc): Inverter, 50kW (twenty) Phases: 1 or 3 3 Rated Output (Prime kW): 1,000ac (Standby kW): o Frequency: 60Hz ted Power Factor (%): >0.99 Rated Volta a (Volts):480Vac Rated Current (Amperes): 60A ergy Source (gas, steam, hydro, wind, etc.) solar photovoltaic F TYPE OF, INTERCONNECTED OPERATION Interconnection / Transfer method: ❑Open ❑ Quick Open ❑ Closed ❑ Soft Loading ❑■ Inverter Proposed use of generation: (Check all that may apply) ❑ Peak Reduction ❑ Standby ❑■ Energy Sales ❑ Cover Load Duration Parallel: ❑ None ❑ Limited ✓ Continuous -Certified System orting Energy nYe/ No (Circle one) ✓ Ye No (Circle one) ESTIMATED LOAD RMATION The following information will be used to help properly design the interconnection. This Information is not intended as a commitment or contract for billing purposes. Minimum anticipated load (generation not operating): kW:0 kVA:0 Maximum anticipated load (generation not operating): kW: 0 kVA: 0 ESTIMATED START/COMPLETION DATES Construction start date: 01 March 2018 Completion (operational) date: 30 April 2018 DESCRIPTION OF PROPOSED INSTALLATION AND OPERATION Attach a single line diagram showing the switchgear, transformers and generation facilities Give a general description of the manner of operation of the generation (cogeneration closed -transition beak shaving open - transition peak shaving emergency power, etc.). Also does the Applicant intend to sell power and energy or ancillary services and/or wheel power over Xcel Energy facilities? If there is an intent to sell power and energy, also define the target market. Please see attached; sale of power to Xcel Energy's Solar*Rewards Community program. (Continued on Sheet No. 10-104 Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company Docket No. E002/GR-05-1428 Order Date: 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 103.doc Northern States Power Company, a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 104 APPENDIX B: Generation Interconnection Application Form (Continued) SIGN OFF AREA: With this Application, we are requesting Xcel Energy to review the proposed Generation System Interconnection. We request that Xcel Energy identifies the additional equipment and costs involved with the interconnection of this system and to provide a budgetary estimate of those costs. We understand that the estimated costs supplied by Xcel Energy, will be estimated using the information provided. We also agree that we will supply, as requested, additional information, to allow Xcel Energy to better review this proposed Generation System interconnection. We have read the "State of Minnesota Distributed Generation Interconnection Requirements" and will design the Generation System and interconnection to meet those requirements. Applicant Name (print): Charlie Nickoloff Applicant Signature: f Date: 25 January 2017 SEND THIS COMPL Q IGNED APPLICATION AND ATTACHMENTS TO THE GENERATION INTERCONNECTION COORDINATOR (Continued on Sheet No. 10-105) Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company Docket No. E002/GR-05-1428 Order Date: 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 104.doc Northern States Power Company, a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 105 APPENDIX C: Engineering Data Submittal Form WHO SHOULD FILE THIS SUBMITTALL: Anyone in the final stages of interconnecting a Generation System with Xcel Energy. This submittal shall be completed and provided to the Generation Interconnection Coordinator during the design of the Generation System, as established in the "State of Minnesota Interconnection Process for Distributed Generation Systems". INFORMATION: This submittal is used to document the interconnected Generation System. The Applicant shall complete as much of the form as applicable. The Applicant will be contacted if additional information is required. OWNER / APPLICANT Company / Applicant: MSC-Scandia0l, LLC Representative: Charlie Nickoloff Phone Number: 612-709-8064 FAX Number: n/a Title: Vice President Mailing Address: 345 St Peter St - Suite 1600, St Paul MN 55102 Email Address: PROPOSED LOCATION OF GENERATION SYSTEM INTERCONNECTION Street Address, Legal Description or GPS coordinates: 23485 Manning Trail N, Scandia MN 55073 PROJECT DESIGN /ENGINEERING (if applicable) Company: Westwood Professional Services Representative: Jack Hays I Phone: 952-265-4871 FAX Number: N/A Mailing Address: 7699 Anagram Dr, Eden Prairie MN 55344 Email Address: ELECTRICAL CONTRACTOR (if applicable) Company: TBD Representative: TBD Phone: TBD FAX Number: TBD Mailing Address: TBD [Email Address: TBD (Continued on Sheet No. 10-106) Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company Docket No. E002/GR-05-1428 Order Date: 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 105.doc Northern States Power Company, a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 106 APPENDIX C: Engineering Data Submittal Form (Continued) TYPE OF INTERCONNECTED OPERATION Interconnection /Transfer method: ❑ Open ❑ Quick Open ❑ Closed ❑ Soft Loading I Inverter Proposed use of generation: (Check all that may apply) Duration Parallel: ❑ Peak Reduction ❑Standby 6 Energy Sales ❑ None ❑ Limited 8 Continuous ❑ Cover Load Person to Contact before remote starting of units Pre -Certified System: Ye No (Circle one) Exporting Energy Yes No (Circle one) GENERATION SYSTEM OPERATION / MAINTENANCE CONTACT INFORMATION Maintenance Provider: Phone #: Pager #: Operator Name: Phone #: Pager #: Person to Contact before remote starting of units Contact Name: Phone #: Pager #: 24hr Phone #: GENERATION SYSTEM OPERATING INFORMATION Fuel Capacity (gals): Full Fuel Run-time (hrs): Engine Cool Down Duration (Minutes): Start time Delay on Load Shed signal: Start Time Delay on Outage (Seconds): ESTIMATED LOAD The following information will be used to help properly design the interconnection. This Information is not Intended as a commitment or contract for billing purposes. Minimum anticipated load (generation not operating): kW: kVA: Maximum anticipated load (generation not operating): kW: kVA: (Continued on Sheet No. 10-107) Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company Docket No. E002/GR-05-1428 Order Date: 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 106.doc Northern States Power Company, a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 107 APPENDIX C: Engineering Data Submittal Form (Continued) REQUESTED CONSTRUCTION START/COMPLETION DATES Design Completion: Construction Start Date: Footings in place: 01 March 2019 Primary Wiring Completion: Control Wiring Completion: Start Acceptance Testing: Generation operational 3� April 20 8 (In-service): (Complete all applicable items. Copy this page as required for additional generators.) SYNCHRONOUS GENERATOR (if applicable) Unit Number: Total number of units with listed specifications on site: Manufacturer: Type: Phases: 1 or 3 Serial Number (each) Date of manufacture: Speed (RPM): Freq. (Hz); Rated Output (each unit) kW Standby: kW Prime: kVA: Rated Power Factor (%): Rated Voltage(Volts): Rated Current (Amperes): Field Voltage (Volts): Field Current (Amperes): Motoring Power (kW): Synchronous Reactance (Xd): Transient Reactance (X'd): Subtransient Reactance (X'd): Negative Sequence Reactance (Xs): Zero Sequence Reactance (Xo): % on % on % on % on % on kVA base kVA base kVA base kVA base kVA base Neutral Grounding Resistor (if applicable): 1 2t or K (heating time constant): Exciter data: Governor data: Additional Information: (Continued on Sheet No. 10-108) Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company Docket No. E002/GR-05-1428 Order Date: 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 107.doc Northern States Power Company, a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 108 APPENDIX C: Engineering Data Submittal Form (Continued) INDUCTION GENERATOR (if applicable) Rotor Resistance (Rr): Rotor Reactance (Xr): Magnetizing Reactance (Xm): Ohms Stator Resistance (Rs): Ohms Ohms Ohms Stator Reactance (Xs): Ohms Short Circuit Reactance (Xd): Ohms Design Letter: Frame Size: Exciting Current: Temp Rise (deg C°): Rated Output (kW): Low Voltage: kV Connection: delta wye ❑ Reactive Power Required: kVars (no Load) kVars (full load) If this is a wound -rotor machine, describe any external equipment to be connected (resistor, rheostat, power converter, etc.) to rotor circuit, and circuit configuration. Describe ability, if any, to adjust generator reactive output to provide power system voltage regulation. kVA base Transformer Resistance (R): % on kVA base Transformer Reactance (X): % on Additional Information: Neutral Grounding Resistor (if applicable) PRIME MOVER (Complete all applicable items) Unit Number: Type: Manufacturer: Serial Number: Date of Manufacture: H. P. Rated: H.P. Max: Inertia Constant: Ib. -ft. Energy Source (hydro, steam, wind, wind etc.): INTERCONNECTION (STEP-UP) TRANSFORMER (If applicable) Manufacturer: I kVA: Date of Manufacture: Serial Number: High Voltage: kV Connection: delta wye ❑ Neutral solidly grounded? Low Voltage: kV Connection: delta wye ❑ Neutral solidly grounded? Transformer Impedance (Z): % on kVA base Transformer Resistance (R): % on kVA base Transformer Reactance (X): % on I kVA base Neutral Grounding Resistor (if applicable) (Continued on Sheet No. 10-109) Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company Docket No. E002/GR-05-1428 Order Date: 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 108.doc Northern States Power Company, a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 109 APPENDIX C: Engineering Data Submittal Form (Continued) TRANSFER SWITCH (If applicable) Model Number: Type: Manufacturer: Rating (amps): INVERTER (If applicable) Manufacturer: Chint Power systems Model: 50kw Rated Power Factor (%): >0.99 Rated Voltage (Volts): 48ovac Rated Current (Amperes): 60A Inverter Type (ferroresonant, st ulse-width modulation, etc.): pulse -width modification Type of Commutation: forced line I Minimum Short Circuit Ratio required: nia Minimum voltage for successfu commutation: 480vao Current Harmonic Distortion Maximum Individual Harmonic t%1: >3% Maximum Total Harmonic Distortion (%): >3i Voltage Harmonic Distortion Maximum Individual Harmonic t%1: >3% Maximum Total Harmonic Distortion (%):>3% Describe capability, if any, to adjust reactive output to provide voltage regulation: power factor adjustable to +/- 80% NOTE: Attach all available calculations, test reports, and oscillographic prints showing inverter output voltage and current waveforms. POWER CIRCUIT BREAKER (if applicable) Manufacturer: Model: Rated Voltage (kilovolts): Rated Ampacit (Amperes): Interrupting Rating (Amperes): BIL Rating: Interrupting Medium (vacuum, oil, gas, etc.) Insulatin Medium (vacuum, oil, gas, etc.) Control Voltage (Closing): (Volts) ❑ AC ❑ DC Control Voltage (Tripping): (Volts) AC 0 DC 013atter hargecl Capacitor Close Energy (circle one): Spring Motor ❑ Hydraulic ❑ Pneumatic ❑Other Trip Energy (circle one): LJ Spring ❑ Motor ❑ Hydraulic ❑ Pneumatic ❑Other Bushing Current Transformers (Max. ratio): I Relay Accuracy Class: CT'S Multi Ratio? (circle one); DNo / Yes: (Available taps): (Continued on Sheet No. 10-110) Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company Docket No. E002/GR-05-1428 Order Date: 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 109.doc Northern States Power Company , a Minnesota corporation and wholly owned subsidiary of Xcel Energy Inc. Minneapolis, Minnesota 55401 MINNESOTA ELECTRIC RATE BOOK - MPUC NO. 2 DISTRIBUTED GENERATION STANDARD Section No. 10 INTERCONNECTION AND POWER PURCHASE TARIFF (Continued) Original Sheet No. 110 APPENDIX C: Engineering Data Submittal Form (Continued) 11 MISCELLANEOUS (Use this area and any additional sheets for applicable notes and comments) 11 SIGN OFF AREA This Engineering Data Submittal documents the equipment and design of the Generation System. We agree to supply Xcel Energy with an updated Engineering Data Submittal any time significant changes are made in the equipment used or the design of the proposed Generation System. The Applicant agrees to design, operate and maintain the Generation System within the requirements set forth by the "State of Minnesota Distributed Generation Interconnection Requirements". Applicant Name (print): Charlie Nickoloff Applicant Signature: Date: 25 January 2017 SEND THIS COMPLETENED ENGINEERING DATA SUBMITTAL AND ANY ATTACHMENTS TO THE GENERATION INTERCONNECTION COORDINATOR (Continued on Sheet No. 10-111) Date Filed: 11-02-05 By: Cynthia L. Lesher Effective Date: 02-01-07 President and CEO of Northern States Power Company E002/GR-05-1428 09-01-06 S:\General-Offices-GO-01\PSF\RA\Rates\Current\Mn elec\Me 10 110.doc