7.b 4 Sandstrom DwgsN UTILITY POLE MOUNTED TRANSFORMER UTILITY BIDIRECTIONAL METER AC COMBINER EXISTING UNDERGROUND LINE UTILITY AC DISCONNECT UTILITY PRODUCTION METER UNDERGROUND LINE (SOLAR EQIPMENT WILL NOT IMPEDE EXISTING SERVICE CLEARANCES) DISCONNECTS AND METER SOCKETS SHALL BE NO MORE THAN 10' APART FROM ONE ANOTHER HOUSE PI L A R R D N PER K I N S A V E N EXISTING METER SOCKET SHALL BE BYPASSED AND NEW METER SOCKET MOVED NEAR SOLAR ARRAY. PROPOSED UNDERGROUND LINE 73' DESCRIPTION#INITIAL DATE SHEET: DRAWING TITLE: SCALE: REVISIONS: 26 7 0 P A T T O N R D R O S E V I L L E M N 5 5 1 1 3 SYSTEM INFORMATION SYSTEM SIZE DC: 13.9KW SYSTEM SIZE AC: 12KW DC/AC RATIO: 1.16 TILT: 30O AZIMUTH: 180O MODULE: (25) QCELL 335W (8) QCELL 320W (9) QCELL 330W INVERTER: (2) SOLAREDGE 6kW OPTIMIZER: (42) P400 RACKING: SCHLETTER PVMAX SITE ADDRESS: JEFF SANDSTROM 15610 PILAR RD N SCANDIA, MN 55073 612-802-1933 1 LAYOUT DESIGN TMP 5-10-2017 65 1 - 7 8 9 - 5 3 0 5 2 XCEL DRAWING TMP 5-31-2017 XCEL COMMENTS3 AAK 6-12-2017 4 METER RELOCATION TMP 6-21-2017 5 AAK 7-5-2017RACKING HEIGHT SITEPLAN SP AS STATED 1/64" = 1' 0" SITE PLAN1 T O B U I L D I N G L O A D S UTILITY TRANSFORMER TO U T I L I T Y House Panel 1ph, 3W, 120/240V, 200A OUTSIDEROOFTOPOUTSIDE ELECTRICAL ROOM (OUTDOORS) EXISTING EQUIPMENTNEW EQUIPMENT NOTE: INDICATES LABEL REQUIRED, SEE DWG E21 200A,1P 22 24 SOLAREDGE SE6000A-US 6kW INVERTER 98% CEC EFFICIENCY 6kW CONTINUOUS OUTPUT POWER MAX OUTPUT CURRENT: 25A MAX INPUT CURRENT: 18A GROUND FAULT PROTECTION PROVIDED PER NEC 690.35 INTEGRATED ARC FAULT PROTECTION UL 1741 CERTIFIED GRID CONENCTION STANDARDS IEEE 1547 SOLAREDGE POWER OPTIMIZER P400 DC INPUT POWER: 400W MAX INPUT VOLTAGE: 80V MPPT RANGE: 8-80V MAX DC INPUT CURRENT: 12.63A MAX OUTPUT CURRENT: 15 6000W STRING MAX Utility AC Disconnect 1ph, 3W, 120/240V, 100A, 3R DISCONNECT SHALL BE UTILITY VISIBLE, LOCKABLE, REDAILY ACCESSIBLE 6 17 Xcel Production Meter 1ph, 3W, 120/240V, 200A, 3R M 1 Utility Bidirectional Meter (Bypass Lever) 400A, 240V 1phase, 3wire M 22 STRING 1 - 22 MODULES STRING 2 - 20 MODULES AC COMBINER 1ph, 3W, 120/240V, 3R 35A,1P 35A,1P 70A,1P 23 PV MODULES: HANWHA Q.CELL Q.PLUS L-G4.1 335W Voc: 46.94V Isc: 9.54A Vmpp: 37.33V Impp: 8.97A Q.PLUS L-G4.1 330W Voc: 46.55V Isc: 9.49A Vmpp: 37.02V Impp: 8.91A Q.PRO L-G4.2 320W Voc: 45.76V Isc: 9.13A Vmpp: 37.53V Impp: 8.53A EXISTING UNDERGROUND LINE TO HOUSE NEW METER SOCKET TO BE NEAR SOLAR ARRAY EXISTING METER SOCKET SHALL HAVE BYPASS SHORT INSTALLED 70A,1P STRING 1 SHALL CONSIST OF (22) 335W PANELS STRING 2 SHALL CONSIST OF (3) 335W PANELS, (8) 320W PANELS, AND (9) 330W PANELS DESCRIPTION#INITIAL DATE SHEET: DRAWING TITLE: SCALE: REVISIONS: 26 7 0 P A T T O N R D R O S E V I L L E M N 5 5 1 1 3 SYSTEM INFORMATION SYSTEM SIZE DC: 13.9KW SYSTEM SIZE AC: 12KW DC/AC RATIO: 1.16 TILT: 30O AZIMUTH: 180O MODULE: (25) QCELL 335W (8) QCELL 320W (9) QCELL 330W INVERTER: (2) SOLAREDGE 6kW OPTIMIZER: (42) P400 RACKING: SCHLETTER PVMAX SITE ADDRESS: JEFF SANDSTROM 15610 PILAR RD N SCANDIA, MN 55073 612-802-1933 1 LAYOUT DESIGN TMP 5-10-2017 65 1 - 7 8 9 - 5 3 0 5 2 XCEL DRAWING TMP 5-31-2017 XCEL COMMENTS3 AAK 6-12-2017 4 METER RELOCATION TMP 6-21-2017 5 AAK 7-5-2017RACKING HEIGHT ONELINE E1 WARNING ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN OPEN POSITION WARNING ELECTRICAL SHOCK HAZARD DC CONDUCTORS ARE UNGROUNDED AND MAY BE ENERGIZED LABEL 6 LABEL 7 MAXIMUM OPERATING CURRENT: MAXIMUM OPERATING VOLTAGE: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED 4" 2" 4" 2" 61 2" 1" 4" 1" 4" 1" LABEL 1 LABEL 17 LABEL 22 WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE OVERCURRENT PROTECTION DEVICE LABEL 24 4" 1" 50A 240V SOLAR AC COMBINER PANEL OUTPUT CURRENT: 50A OPERATING VOLTAGE: 240V NEUTRAL WIRE IS SIZED PER EGC FOR CURRENT SENSING ONLY. DO NOT CONNECT ADDITIONAL LOADS TO ACCUMULATION PANEL WITHOUT PROPER ENGINEERING SUPERVISION AND PV SYSTEM OWNER'S FORMAL APPROVAL. 6" LABEL 23 UTILITY OWNED PRODUCTION METER UTILITY AC DISCONNECT DESCRIPTION#INITIAL DATE SHEET: DRAWING TITLE: SCALE: REVISIONS: 26 7 0 P A T T O N R D R O S E V I L L E M N 5 5 1 1 3 SYSTEM INFORMATION SYSTEM SIZE DC: 13.9KW SYSTEM SIZE AC: 12KW DC/AC RATIO: 1.16 TILT: 30O AZIMUTH: 180O MODULE: (25) QCELL 335W (8) QCELL 320W (9) QCELL 330W INVERTER: (2) SOLAREDGE 6kW OPTIMIZER: (42) P400 RACKING: SCHLETTER PVMAX SITE ADDRESS: JEFF SANDSTROM 15610 PILAR RD N SCANDIA, MN 55073 612-802-1933 1 LAYOUT DESIGN TMP 5-10-2017 65 1 - 7 8 9 - 5 3 0 5 2 XCEL DRAWING TMP 5-31-2017 XCEL COMMENTS3 AAK 6-12-2017 4 METER RELOCATION TMP 6-21-2017 5 AAK 7-5-2017RACKING HEIGHT LABELS E2 LABELS SHALL BE WEATHERPROOF, DURABLE, PERMANATELY MOUNTED, AND COMPLY WITH NEC 690 22'-91 2" UTILITY SERVICE POLE XFRMR EXISTING UNDERGROUND LINE PROPOSED UNDERGROUND LINE ADDITION PROPOSED SPLICE DESCRIPTION#INITIAL DATE SHEET: DRAWING TITLE: SCALE: REVISIONS: 26 7 0 P A T T O N R D R O S E V I L L E M N 5 5 1 1 3 SYSTEM INFORMATION SYSTEM SIZE DC: 13.9KW SYSTEM SIZE AC: 12KW DC/AC RATIO: 1.16 TILT: 30O AZIMUTH: 180O MODULE: (25) QCELL 335W (8) QCELL 320W (9) QCELL 330W INVERTER: (2) SOLAREDGE 6kW OPTIMIZER: (42) P400 RACKING: SCHLETTER PVMAX SITE ADDRESS: JEFF SANDSTROM 15610 PILAR RD N SCANDIA, MN 55073 612-802-1933 1 LAYOUT DESIGN TMP 5-10-2017 65 1 - 7 8 9 - 5 3 0 5 2 XCEL DRAWING TMP 5-31-2017 XCEL COMMENTS3 AAK 6-12-2017 4 METER RELOCATION TMP 6-21-2017 5 AAK 7-5-2017RACKING HEIGHT SERVICE E3 UTILITY BIDIRECTIONAL METER (400A) UTILITY PRODUCTION METER UTILITY AC DISCONNECT AC COMBINER PANEL INVERTERS DESCRIPTION#INITIAL DATE SHEET: DRAWING TITLE: SCALE: REVISIONS: 26 7 0 P A T T O N R D R O S E V I L L E M N 5 5 1 1 3 SYSTEM INFORMATION SYSTEM SIZE DC: 13.9KW SYSTEM SIZE AC: 12KW DC/AC RATIO: 1.16 TILT: 30O AZIMUTH: 180O MODULE: (25) QCELL 335W (8) QCELL 320W (9) QCELL 330W INVERTER: (2) SOLAREDGE 6kW OPTIMIZER: (42) P400 RACKING: SCHLETTER PVMAX SITE ADDRESS: JEFF SANDSTROM 15610 PILAR RD N SCANDIA, MN 55073 612-802-1933 1 LAYOUT DESIGN TMP 5-10-2017 65 1 - 7 8 9 - 5 3 0 5 2 XCEL DRAWING TMP 5-31-2017 XCEL COMMENTS3 AAK 6-12-2017 4 METER RELOCATION TMP 6-21-2017 5 AAK 7-5-2017RACKING HEIGHT EQUIPMENT E4 NTS Equipment Detail1 36'-7" 11'-4" 16' 33'-3" DESCRIPTION#INITIAL DATE SHEET: DRAWING TITLE: SCALE: REVISIONS: 26 7 0 P A T T O N R D R O S E V I L L E M N 5 5 1 1 3 SYSTEM INFORMATION SYSTEM SIZE DC: 13.9KW SYSTEM SIZE AC: 12KW DC/AC RATIO: 1.16 TILT: 30O AZIMUTH: 180O MODULE: (25) QCELL 335W (8) QCELL 320W (9) QCELL 330W INVERTER: (2) SOLAREDGE 6kW OPTIMIZER: (42) P400 RACKING: SCHLETTER PVMAX SITE ADDRESS: JEFF SANDSTROM 15610 PILAR RD N SCANDIA, MN 55073 612-802-1933 1 LAYOUT DESIGN TMP 5-10-2017 65 1 - 7 8 9 - 5 3 0 5 2 XCEL DRAWING TMP 5-31-2017 XCEL COMMENTS3 AAK 6-12-2017 4 METER RELOCATION TMP 6-21-2017 5 AAK 7-5-2017RACKING HEIGHT DIM1 9' - 4 5 16 " DESCRIPTION#INITIAL DATE SHEET: DRAWING TITLE: SCALE: REVISIONS: 26 7 0 P A T T O N R D R O S E V I L L E M N 5 5 1 1 3 SYSTEM INFORMATION SYSTEM SIZE DC: 13.9KW SYSTEM SIZE AC: 12KW DC/AC RATIO: 1.16 TILT: 30O AZIMUTH: 180O MODULE: (25) QCELL 335W (8) QCELL 320W (9) QCELL 330W INVERTER: (2) SOLAREDGE 6kW OPTIMIZER: (42) P400 RACKING: SCHLETTER PVMAX SITE ADDRESS: JEFF SANDSTROM 15610 PILAR RD N SCANDIA, MN 55073 612-802-1933 1 LAYOUT DESIGN TMP 5-10-2017 65 1 - 7 8 9 - 5 3 0 5 2 XCEL DRAWING TMP 5-31-2017 XCEL COMMENTS3 AAK 6-12-2017 4 METER RELOCATION TMP 6-21-2017 5 AAK 7-5-2017RACKING HEIGHT DIM2 STANDARD, PVMAX3, 72 CELL, 30DEGREES, TRIANGLE NTS Racking Dimensions1