Loading...
5.c) Goose Lake Storm Water Retrofit Project ! � Meeting Date: 10/6/09 Agenda Item: � C � , City Council Agenda Report City of Scandia 14727 209'h St. North Scandia, MN 55073 (651) 433-2274 Action Requested: Approve water quality-related improvements to the city's Goose Lake Landing proposed by the Washington Conservation District (WCD.) Deadline/ Timeline: Approval is requested so construction can occur yet this year. Background: • The WCD has secured funding from for stormwater management retrofit projects to treat runoff generated from boat launches and the adjacent impervious areas. Runoff increases nutrient and sediment inputs to lakes and causes erosion issues. • Goose Lake in Scandia and Lily Lake in Stillwater were the selected sites. These projects will serve as models for boat launch stormwater retrofits elsewhere in the county. • The proposed plan is attached. The engineer met with staff(Public Works Maintenance Supervisor John Morrison and Administrator Hurlburt) at the site to discuss the plan. The planned improvements should not have a negative impact on the function of the boat launch, nor will they interfere with the dry hydrant on the south side of the site. • There would be no cost to the city for the project. The city will continue to be responsible for maintenance. Staff has no particular concerns, except that the plantings in the retention/rain garden area should be low maintenance materials (such as shrubs) rather than plants that would require more maintenance, such as periodic weeding. • A representative of either the WCD or the Carnelian-Marine-St. Croix Watershed District will be present at the Council meeting to answer questions about the project. Recommendation: I recommend that the Council review the plan, and consider approving it with any conditions you deem appropriate. Staff recommends that approval be contingent upon installation of low-maintenance plant materials. Attachments/ • Location Map Materials provided: . Project Plan Contact(s): Amy Carolan, WCD 651 275-1136 Ext. 22 Prepared by: Anne Hurlburt, Administrator (goose lake boat launch improvements) Page 1 of 1 10/O 1/09 , � General Location Map - Goose Lake, Scandia, MN MAPaNEST. o�aoo m izoo st �o �� ¢ A��di z RO�H � �v�, � � '_ � z � lf� Goose Lake � � Boat Launch � � �� ! �� � � � � � � 3 '�.,,, �ake t' � Qy rsO°� I Z 22Uth St N :��'L z � /� v .. d � - 3c ��� � � � ,�' � -- $' ;`; 1 � z ' ' ,r;� � �et# �, 215th St N � ���P � �'�`, 214th�t N �� �� i� �, ,, Scandia TH N __ __ x , � ` _.., -- ._ — _ - � — --=�cdndW Trt N — -- _ _ _ , _ � �- ��__. , O�ark Ct N? <: . ��� `° C}`. `,Scandla � � ,t,r� �o `� _�, : � . � �� �`�� a,�T�' '�;�;, �'� - � �:___ _ _- - --- � �. , #.. zasm.s�a _ _ ;' ..,;��_ , 2�2009 AiepQuest Inc. �'' M�Data 6,^2009 NAYTEO dr TefeAtlas � � t � d ;^ �� �� � _ :� , � ...��_,��-,�+t :��. , � ,' »a '�I�� �.:.. Yf,N�; '�•�Kii-wic�ak.f� 4�:� hi I���,I'� . R`. � �� Uoose Lake ID 82-0059-00 ,�;�- �; �,�,� �� �,,�� Goose Lake OHW 983.9 � . 3 :.� + . ` � �� , `� �fF�„ Notes: �` �'��� + �'�- `'� � '� ,� . All work to be completed � '� � °� � ,� � ;���'"� upgradient of OHW � ._ ,� _ ,�; �� ,, <. ,� ; Stake OHW elevation in � � � �''�r "� � field nor to construction � E.� ,"�. Replace existing gravel with P P , � . ;, compacted Dressers Trap stone. � � - Remove top 6 inches of gravel � ` {;��� _ °•, and dispose of with City of Scandia �� - Backfill with Dressers Trap stone, ��F � �X compact, and blend to meet ����2US; } '� , �, � existing adjacent c�rades �P ��`' �. ' .� ���.�,�, . ���, M �} ,�. � '��, ,�.''��. S,�Y'� o� �� . �� . �'� � ���.,� Rip-rapped overflow section. �< '`��» , � � r ",� � :� � _ � x , �`� `� Grade shallow retention area. �ep, v�, �� " � ; - Maximum depth from rip-rapped ����,,���,_i�,,, overflow equals 2 feet �s<<�� ' < <«<i �'����� . +'� � , - Minimum storage volume below ?��'�`�`c�� � ' ��; �+ 3 ;, rip-rapped overflow equals 350 cubic feet � �` , . ,�;� �� - Place topsoil, plant to GRG specifications ,� 5�' r ��` ., '��� :�,�x, Fill in washes on either ` � side of landing with compacted Impervious A'a Dressers Trap stone 25(19 Sy.Ft. _� �',:��w�i4r ` � Install grated trench drain . ` +�` across landing (dimensions) }`4. l R �il�. 403220220001 �' �L= � � Ft � r ��. , �` � - � ,. , ; � �a��.��, '.'� �� � Fill in washes on either k•� "�`* w .� � , .� ` ��; side of landing with compacted �� ��° _„ -�:> ����+�� , Dressers Trap stone � °:� y �x � '' �.� `,�r ... 4�,,;�' r � � 3� � Redirect channel discharge away Install 2 low ditch blocks F�`�z_ from boat landing to grassed area �' ' in existing drainage channel. directly east; regrade lower end of ��, swale and depression as necessary '� and revegetate/restore as per Note: GRG specification Tax Parcels,Contours and Aerial Photographs �, from Washington Conservation District N "�� !'r�' 30 15 0 30 �, ' �� y Feet f��� ` �_.'. Mxd:L:�2343\Dltrnxd\Uoose Lake Site Imprwement Map 9-28-09 mxd � . �� 4 Last ModHied:9/28/2009 3:42:36 PM � � �� WASHINGTON CONSERVATION DISTRICT o � Wenc < SEP 2009 Wenck Associates,Inc 1800 Pioneer Creek Center 9_28_�g Goose Lake Landing Site Improvement Map - DRAFT Environmental Engineers Maple Plain,MN 55359-0429