6.a) Ganzel CommentsFrom: Pete Ganzel [mailto:Pete.Ganzel@co.washington.mn.us] Sent: Thursday, August 28, 2014 8:30 AM To: Sherri A. Buss Subject: RE: Septic and Well 16987 197th St Sherri: I went out and looked at the site yesterday. The soil conditions will require a non-standard mound with a 3ā€™ sand base. Wetlands have been delineated and it looks like the absorption area of the mound will be about 20ā€™ from the delineation on the south side. There is a little pocket within the mound area which is at a same elevation as some of the delineated area and has wetland vegetation (skunk cabbage). A large white pine will be within the upslope dike of the mound but this can be reduced a little by turning the mound a little to the east on the south end. A pump line will have to be installed under the creek/seep from the proposed tank location to the mound. The proposed well location is next to a privy and the existing septic and pump tanks so there may be a better location. Iā€™m assuming this will be looked at by DNR and NPS since the entire area is likely within a scenic easement. Pete Ganzel Senior Environmental Specialist (651)430-6676