7.b PC Staff Report_Melcher Variance
TKDA ® | 444 Cedar Street Suite 1500 | Saint Paul, MN 55101 651.292.4400 • tkda.com
An employee -owned company promoting affirmative action and equal opportunity.
Memorandum
To: Scandia Planning Commission Reference: Melcher Variance Application
Copies To: Brenda Eklund, Clerk
Ken Cammilleri, City
Administrator
Forrest and Natalie Melcher,
Applicants
Project No.: 18108.000 Melcher Variance
From: Evan Monson, Planner Routing:
Date: May 27, 2021
SUBJECT: Variances to: construct a detached garage closer to the right-of-way than the
house, and to construct an accessory structure exceeding the requirements
permitted for parcels between 1 and 3 acres in size
MEETING DATE: June 1, 2021
LOCATION: 12620 181st St N, PID 33.032.20.44.0004
APPLICANT/OWNER: Forrest and Natalie Melcher
ZONING: General Rural (GR), Shoreland Overlay
REVIEW PERIOD: June 14, 2021, 120-day August 13, 2021
ITEMS REVIEWED: Application and plans received March 15, 2021, revised plans received May
27, 2021
DESCRIPTION OF THE REQUEST
The applicant is requesting to build a detached accessory structure on the southeast corner of their
property. The structure would be 48 feet by 42 feet, with a 10 feet by 20 feet lean-to on the southeast side
of the structure. The structure would be used for storage of personal vehicles and equipment, as well as
provide space for a shop and woodworking area. The structure would need an access from 181st Street
North, which terminates near the proposed location.
The proposed accessory structure (including the lean-to) has a footprint of 2,216 square feet. The
structure is proposed to be placed a minimum of 40 feet from the front property line. It would be closer to
the road right-of-way (ROW) than the house on the property. The size of the structure would also exceed
what is currently permitted in the Development Code for parcels between one and three acres in size .
These three issues trigger a variance, hence the request from the applicant.
Melcher Variance Staff Report June 1, 2021
Scandia Planning Commission Page 2
PROPERTY INFORMATION
Parcel description: 12620 181st Street North is located on the south side of the city, south of Big Marine
Lake in the Hardwood Hills subdivision. There are a number of waterbodies near the property, so the area
is within the Shoreland Overlay zoning district. No waterbodies or wetlands are within close proximity of
the parcel, though. The parcel is approximately 2.39 acres in size, which makes it nonconforming to the
minimum lot sizes required in the applicable zoning districts. The impervious surfaces on the lot total less
than 10% of the property. An existing house with an attached garage is located on the far northeast
corner of the lot, with the septic system located to the west. The lot slopes from the northeast and
southwest corners down towards the center of the lot. The lot is wooded apart from a small clearing near
the road; this is the proposed location of the new accessory str ucture.
Figure 1: Aerial of the property
Zoning: GR, Shoreland Overlay
Land use: Single-Family Residential
EVALUATION OF VARIANCE REQUEST
Applicant’s Explanation of the Plan and Variance Request
“We are requesting permission to construct an accessory structure on our property. Due to the placement
of the principal structure on the lot, and location of septic system and utilities, it would be impossible to be
as far from the right of way as the principal structure, as required in the zoning ordinance. In addition to
Melcher Variance Staff Report June 1, 2021
Scandia Planning Commission Page 3
this, the principal structure is already non-compliant with current setback requirements, and adding onto
this could only further infringe upon the requirements which we would like to respect. Please see attached
site plan for illustration and details. The proposed location would be minimally disruptive to the natural
slope and drainage, as well as adjacent properties. It would be compliant with all required setbacks in the
zoning ordinance. Please also note the location of the property at the dead end of 181st Street North and
absence of any residences in close proximity. We love this community and truly believe this would not
cause any significant disturbance. Thank you for your consideration.”
Staff Comments on the Variance Request
Engineer
The City Engineer provided the following comments regarding the request.
If new driveway access is requested, Driveway access permit will be required through Public
Works and potentially require a driveway culvert to be installed along with some potential
ditch grading.
Site improvements shall be within compliance of the Watershed District. Stormwater
management improvements shall be anticipated as conditions of approval for their permit.
Proposed improvements will result in loss of some tree canopy and discussion on if tree
replacement plan should occur to show tree replacements on the final plans if required.
Proposed project will disturb fifty (10) cubic yards or more and/or disturbance of 600 square
feet or more, thus a grading permit will be required.
Soil piles and exposed vegetation areas must be contained with erosion control devices,
including multi rows of erosion control considering how steep the slopes are on this site.
Temporary restoration may be required to contain any erosion. Upon completion of the
grading, site restoration shall be completed as soon as possible.
Verify proposed finish floor elevation of the new garage and show on final plans.
Watershed
The CMSCWD indicated the following rules would be applicable:
Rule 2 Stormwater Management – Adding impervious surface that exceeds either one acre or five
percent of the site (5,205-SF). Factoring in the amount of existing impervious, the proposed
project will result in the lot exceeding 5% impervious. Stormwater management providing at least
330-CF of storage is required, maybe more if an access drive is also proposed. Onsite soils are
HSG A, therefore bio retention is recommended.
Rule 3 Erosion Control – An erosion/sediment control plan will be required, along with details for
vegetation establishment will be required.
Rule 7 Floodplain – Compliance with low floor freeboard requirement of stormwater BMPs will be
required.
DNR
The East Metro Area Hydrologist did not provide comments at the time of this staff report.
Development Code
The front setback for the GR zoning district is 40 feet, as noted in Chapter Two, Section 2.6(7). The rear
setback for this zone is 50 feet, while the side setback is 20. The proposed accessory structure is located
Melcher Variance Staff Report June 1, 2021
Scandia Planning Commission Page 4
at a minimum 40 feet from the front property line along the ROW . The existing house is located within the
rear setback, and is approximately 17 feet from the east side setback.
The Development Code notes in Chapter Two, Section 3.2 the standards for accessory structures.
Section 3.2(2)(B) notes that no accessory structure is able to be closer to the road right-of-way (ROW)
than the principal structure on a lot unless a number of criteria and all setbacks are met.
(B) No detached accessory structure, including storage sheds, shall be located closer to the
road right-of-way in relation to the front lot line than the principal building on a lot unless the
following conditions are met:
1. The parcel is located on a lakeshore. Accessory structures on lakeshore parcels
may be located between the roadway right-of-way and principal building and shall meet
setback requirements; or
2. The accessory structure is located on a lot of five (5) acres or more and is placed
at least 200 feet from the road right-of-way; or
3. The accessory structure is located on a parcel that is less than five (5) acres in
size, is necessary to meet the Exterior Storage requirements of this Chapter, and the
physical conditions on the parcel (including but not limited to steep slopes, locations of
wetlands, location of the principal structure) prevent the locatio n of the storage structure
within the side or rear yard; and
Permit required. The property owner shall submit a plan for the proposed structure and
obtain an administrative permit authorizing the location of the structure in the front yard.
The Zoning Administrator may require screening if needed to protect views from adjacent
properties or public roadways.
4. In situations 1-3 above, all setbacks and impervious cover requirements are met.
The first two conditions do not apply to this parcel, as the lot is not on a lake and i s not 5 acres or more in
size. The third criteria could be applicable, though the applicant is currently following the exterior storage
standards.
Based off the location of the existing house (the principal structure), an accessory structure is unable to
be built on most of the property, as most of the lot is between the ROW and the house. Building the
proposed detached structure to the side or the rear of the house could likely need a variance, given the
location of the house relative to the side and rear setbacks. There is space to the west of the house,
though this is where the septic system is located. Further west the lot slopes down, so significant grading
and removal of trees would be needed to build a detached accessory structure over there that meets
setbacks and is no closer to the ROW than the house. For the same reasons above, if the applicant were
to incorporate the shop space as an addition onto the house, the only feasible locations would be the
front of the existing house.
Section 3.2(3)(C) notes that lots between 1 and 3.0 acres in size are limited to one accessory structure
and 1,000 SF of accessory space. The proposed structure would total 2,216 square feet in size. Since
this parcel is 2.39 acres in size, it is limited to one structure totaling 1,000 square feet in size. Given the
presence of an attached 576 SF garage already on the lot, the proposed request would exceed these
Melcher Variance Staff Report June 1, 2021
Scandia Planning Commission Page 5
thresholds. The property, even with the addition of the proposed accessory structure would still be well
below the permitted impervious surface coverage limit of 25% of the lot.
Variance Criteria and Findings
Chapter One, Section 6.0 of the Development Code includes the criteria and required process for
considering variance requests. Each item to be considered for a variance is identified below in italics,
followed by the Planner’s findings regarding the requested variances.
Variances shall only be permitted when they are in harmony with the Comprehensive Plan and
general purposes and intent of the official control.
The Comprehensive Plan does identify the area as having ‘outstanding ecological quality’; the
proposed location would be less intrusive than other conforming spots on this property. The
request is in general harmony with the Comprehensive Plan and Development Code.
The property owner proposes to use the property in a reasonable manner under the conditions
allowed by official control(s).
The current use of the property is single-family residential, which would not change if this
variance request is approved. Proposing to continue to use the property for residential use is a
reasonable use.
The practical difficulties are not caused by the landowner and are unique to the property.
The practical difficulties limiting the locations to build the proposed structure are due to the
current house being nonconforming, as well as the location of the existing septic system. Based
off the current code requirements, this proposed structure would normally need to be to the side
or rear of the house. Based off the location of the existing house and septic, this is difficult to do
without a variance of some kind. The practical difficulties of the lot being non-conforming are not
caused by the current landowner and are unique to the property.
The variances would not alter the essential character of the area.
The use and function of the property would remain residential, as is the use of other nearby lots in
the area. The roadway terminates near where the structure would be built. The addition of a new
structure may stand out, as not many buildings are within clear view of the right-of-way, though
given its use and the area’s limited traffic, it should not negatively alter the character of the
neighborhood. Granting the variance would not alter the essential character of the area.
Economic conditions alone shall not constitute practical difficulties.
The practical difficulties are related to the existing principal structure not meeting the current
setbacks required by the code. The practical difficulties are not only economic in nature.
The proposed variance will not impair an adequate supply of light and air to adjacent property, or
substantially increase the congestion of the public streets, or increase the danger of fire, or
endanger the public safety, or substantially diminish or impair property values within the
neighborhood.
Granting the requested variances would not result in limiting light or air to neighboring properties .
The land use will still be single-family residential, so increases to congestion, fire danger, or
public safety are not expected. The property values of neighboring values should not be
negatively impacted, either, if the requested variances are granted. The requested variances will
Melcher Variance Staff Report June 1, 2021
Scandia Planning Commission Page 6
not impair the supply of light or air to adjacent properties, increase congestion, endanger the
public, or substantially diminish or impair property values in the neighborhood.
The requested variance is the minimum action required to eliminate the practical difficulty.
Many of the locations that would be to the rear and side of the existing principal structure are
either also within setback areas, or are already occupied. A conforming detached accessory
structure could be built in the northwest corner of the lot, though it is not an ideal location due to
slopes and needing to clear the area of trees. Given the location of the house, adding onto the
house to provide additional storage space would be limited to only the front. The proposed size
would exceed what is normally permitted, though the additions would still leave the lot well below
the impervious surface coverage limit. The requested variance appears to be the minimum action
required to eliminate the practical difficulty, though conditions can be added to ensure the request
is the minimum action required.
Practical difficulties include, but are not limited to, inadequate access to direct sunlight for solar
energy systems.
The variance is not related to a need for direct sunlight for solar energy systems.
The findings support granting the requested variances.
ACTION REQUESTED
The Planning Commission can recommend to the Scandia City Council that it do one of the following:
1. Approve
2. Approve with conditions
3. Deny with findings
4. Table the request
PLANNING STAFF RECOMMENDATION
The Planner recommends that the Planning Commission recommend approval of variances to construct a
detached garage closer to the right-of-way than the house, and to construct an accessory structure
exceeding the requirements permitted for parcels between 1 and 3 acres in size, at 12620 181st Street
North. The following conditions for the variances are recommended:
1. The proposed detached accessory structure shall not exceed 2,216 square feet in size.
2. The applicant shall secure applicable permits from the Carnelian Marine St. Croix Watershed
District, and comply with their requirements.
3. A grading plan and erosion control plan shall be submitted to the City for review prior to
issuance of a building permit, showing any areas of soil disruption, in order to ensure that
drainage is not directed to adjacent properties and proper erosion control measures are
taken.
4. A driveway access permit shall be acquired from the City.
Melcher Variance Staff Report June 1, 2021
Scandia Planning Commission Page 7
5. Finished floor elevations for the proposed structure shall be shown on final plans.
6. The applicant shall secure any other applicable Federal, State, County, and local permits
required for the project.
7. The applicant shall pay all fees and escrows associated with this application.